UK
Electronic Preset Counter E89005
7
3.1.2 Output operations
●
Add, Sub, AddAr, SubAr, AddBat, SubBat, AddTot, SubTot, Trail, TrailAr
3.2 Inputs
3.2.1 INP A, INP B
Signal inputs: function acc� to operating mode�
Max� frequency 60 kHz, can be damped in the programming menu to 30 Hz�
●
Pulse counter: Count inputs
●
Timer: Start input or Start/Stop inputs
●
Frequency meter: Frequency inputs
3.2.2 RESET
Dynamic reset input: resets the pulse counter or timer to zero (adding mode)
or to preset value 2 (subtracting mode)� The reset input can be inhibited in the
programming menu�
●
Pulse counter: RESET input
●
Timer: RESET input
●
Frequency meter: no function
3.2.3 GATE
Static gate input: function depending on operating mode�
●
Pulse counter: no counting while active
●
Timer: no time measurement while active (Gate�hi), no time measurement while
not active (Gate�Lo)�
●
Frequency meter: no counting while active
3.2.4 LOCK INPUT
Static keypad lock input for presets or programming� Lock-out level can be set in
the programming menu�
3.2.5 MPI
Input� Programmable as Display Latch, Set or Teach-In input�