background image

 

GPM - 312

   

COUNTER     

INSTRUCTION MANUAL

100 Taskant street, B.R. Puram, Peelamedu, 

Coimbatore - 641004.Phone no : 0422 4218101

GREEN MICROELECTRONICS INDIA PVT. LTD.

 Manufacturer

Thank you very much for purchasing  this GREEN product GPM - 312.
Please read the instruction manual carefully for the full usage of this product

The counter has passed various quality tests before despatch. Please check however,
at the time of arrival, its model code and its appearance and ensure that all the contents 
are provided and there are no faults, damage etc, to the counter. Please also ensure that  
the model code ,which is labeled on the counter, is identical to the one you ordered.

Note :

1. Our company shall not be liable for any damages, as described below, caused to both 
    any users and third parties
 a) Damages caused by the result of operation of the product.
 b) Damages caused by any defects in the product which are unpredictable for us. 

2. The content in this manual are subject to change without any notice. If you have any 
suggestion on the matter, Please do not hesitate to contact us.  

GREEN

COMPONENTS FOR AUTOMATION

TM

Introduction 

Precaution for safe use

(1)   Use and store the Counter within the specified ambient temperature and humidity
        ranges.

(2)   Do not use the product in location subject to vibrations or shocks. Using the product
       in such location over a long period may result in damage due to stress.

(3)   Do not use the product in locations subject to dust, corrosive gases, or direct sunlight

(4)  Separate the input signal devices, input signal cables and the product from the source 
       of noise or high - tension cables producing noise.

  - mail : greenmicroelectronics@airtel

.in

e

mail

   -   www.greenelectronics.in

(5)  The supplied power voltage and load must be within the rated and specified ranges.

(6)  Do not use where the water or oil splatter on the counter

(7)  Install a switch or circuit breaker that allows the operator to immediately turn off the
      power    

.

   Display                                                                 

Six digits, 0.4 Inch seven segment LED  

User programming                                                

3  Keys  &  Display

                                                   Two relay, 1 c/o 

   Output                                                                     

Relay contact rating           

10 A  @ 230 VAC  

 (Resistive load)

 / 30 VDC

Power consumption                                                

1.5 VA

    Reset : Auto                                                                

Auto reset Time 0.01 Sec to 0.99 Sec  

    Range                                                                   

999 999  Counts

Count direction                                                     

  Up

SPECIFICATIONS  

Front panel

Rear panel - Connection diagram

  Dimensions

48

96

External dimensions 

Panel cutout dimensions

All dimensions are in mm

75

10

90

45

Supply voltage                                                                    

85 - 265 VAC

Weight                                                                    

170  grams

Dimension            

( L  x W x D) 

96 x 48 x 75

Mechanical life of relay                                                                    

Electrical life of relay                                                

Ambient temperature                                                              

Ambient humidity                                                                                35 to 85 % RH                                                                   

Storage temperature                                                         

   10 million operation 

  100.000 operation 

  -10 to 55 c 

  -25 to 65 c  

Operating voltage range                                                                     + / -10% from the rated voltage                                                                               

In the pack                                                                                          counter, side clamp and instruction manual                                                               

Wiring diagram

GPM - 312

COUNTER

GREEN

SET

I / P PULSE

RELAY

GPM - 302

COUNTER

GREEN

SET

I / P PULSE

RELAY

   Input                                                                                                       PNP Proximity unit 

   Pulse frequency                                                                                     Low  : Less  than 30 Hz  & High :  More than 30 Hz                                                                    

   Special feature                                                                                      Memory Retension                                                                    

   Indications                                                                                              Input Pulse and Relay ON                                                                      

   Set points                                                                                               Two (Count and auto reset time)                                                                     

1

9

2

3

4

10

5

11

13

6

7

8

14

16

24 VDC

 REACH RLY 

NO       C                NC

SEN 1 

 

SEN 2 

LIFT RELAY

NO    

C               

NC

O / P

O / P

SUPPLY

15

12

85 - 265  VAC

LED

LED

GREEN

GREEN

PNP 

PROXIMITY

PNP 

PROXIMITY

P

 

  N  