More functions in the ecomatmobile controller
Counter functions for frequency and period measurement
213
10.1.8
Function FAST_COUNT
Contained in the library:
ifm_CRnnnn_Vxxyyzz.LIB
Available for the following devices:
•
CabinetController: CR0301, CR0302, CR0303
•
ClassicController: CR0020, CR0032, CR0505
•
ExtendedController: CR0200, CR0232
•
PCB controller: CS0015
•
SafetyController: CR7020, CR7021, CR7032, CR7200, CR7201, CR7232, CR7505, CR7506
•
SmartController: CR2500, CR2501, CR2502
•
PDM360 smart: CR1071
Function symbol:
FAST_COUNT
ENABLE
CV
INIT
CHANNEL
MODE_UP_DOWN
LOAD
PV
Description
FAST_COUNT operates as counter block for fast input pulses.
This function detects fast pulses at the FRQ input channels 0...3. With the FRQ input channel 0
FAST_COUNT operates like the block CTU. Maximum input frequency
→
data sheet.
NOTE
For the
ecomat
mobile
controllers channel 0 can only be used as up counter. The channels 1...3 can
be used as up and down counters.