ifm
System Manual
ecomat
mobile
SmartController (CR2500, CR2502) V05
CAN in the ecomatmobile controller
Use of the CAN interfaces to SAE J1939
151
Parameters of the function inputs
Name
Data type Description
ENABLE
BOOL
TRUE: function is executed
FALSE: function is not executed
CONFIG
BOOL
TRUE (only for 1 cycle):
for the configuration of the data object
FALSE: during further processing of the program
PG
BYTE
Page address (normally = 0)
PF BYTE
PDU
Format
Byte
PS
BYTE
PDU Specific Byte
DST DWORD
Target
address
of the array in which the received data is
stored
RPT
TIME
Monitoring time
Within this time window the messages must be received
repeatedly. Otherwise, an error will be signalled.
If no monitoring is requested, RPT must be set to T#0s.
LIFE
BYTE
Number of permissible faulty monitoring calls
Parameters of the function outputs
Name
Data type Description
RESULT
BYTE
0 = Not active
1 = Data has been received
3 = Signalling of errors:
Nothing has been received during the time window
(LIFE*RPT)
DEVICE
BYTE
Device address of the sender
LEN
WORD
Number of bytes received