PWM in the ecomatmobile controller
Hydraulic control in PWM
187
Mode 0:
characteristic curve linear for the
range XL to XH
Mode 1:
Characteristic curve linear with dead
band
Values fixed to:
Dead band:
0…10% of 1000 increments
Mode 2:
2-step linear characteristic curve with
dead band
Values fixed to:
Dead band:
0…10% of 1000 increments
Step:
X = 50 % of 1000 increments
Y = 20 % of 1000 increments
Characteristic curve mode 3:
Curve rising (line is fixed)