CAN in the ecomatmobile controller
ifm CANopen library
119
Parameters of the function inputs
Name
Data type Description
CLEAR_ERROR_FIELD BOOL
TRUE: deletes
the contents of the array ERROR_FIELD
FALSE: function is not executed
Parameters of the function outputs
Name
Data type
Description
ERROR_REGISTER
BYTE
Shows the content of the object directory index 1001
h
(Error Register).
ERROR_FIELD
ARRAY [0...5] OF
WORD
The array [0...5] shows the contents of the object
directory index 1003
h
(Error Field).
ERROR_FIELD[0]: number of stored errors.
ERROR_FIELD[1...5]: stored errors, the most recent
error is in index [1].