ifm
System Manual
ecomat
mobile
SmartController (CR2500, CR2502) V05
Operating states and operating system
Operating
states
35
5
Operating states and operating system
Operating states ........................................................................................................................35
Status LED.................................................................................................................................36
Load the operating system ........................................................................................................37
Operating modes .......................................................................................................................37
5.1 Operating
states
After power on the
ecomat
mobile
controller can be in one of five possible operating states:
5.1.1
Reset
This state is passed through after every power on reset:
•
The operating system is initialised.
•
Various checks are carried out.
•
This temporary state is replaced by the Run or Stop state.
> The LED lights orange for a short time.
5.1.2
Run state
This state is reached in the following cases:
•
From the reset state (autostart)
•
From the stop state by the Run command
- only for the operating mode = Test (
→
chapter TEST mode,
→
page
)
5.1.3
Stop state
This state is reached in the following cases:
•
From the reset state if no program is loaded
•
From the Run state if:
- the stop command is sent via the interface
- AND: operating mode = Test (
→
chapter TEST mode,
→
5.1.4
Fatal error
The
ecomat
mobile
controller goes to this state if a non tolerable error was found. This state can only
be left by a reset.
> The LED lights red.