CAN in the ecomatmobile controller
ifm CANopen library
137
Example:
Parameters of the function inputs
Name
Data type
Description
GLOBAL_START
BOOL
TRUE: all connected network participants (slaves) are
started simultaneously during network initialisation.
FALSE: the connected network participants are started
one after the other.
Further information
→
chapter Starting the network with
GLOBAL_START (
→
page
)
CLEAR_RX_OVERFLOW_FLAG
BOOL
FALSE
→
TRUE (edge):
Delete error flag "receive buffer overflow"
FALSE: function is not executed
CLEAR_RX_BUFFER
BOOL
FALSE
→
TRUE (edge):
Delete data in the receive buffer
FALSE: function is not executed
CLEAR_TX_OVERFLOW_FLAG
BOOL
FALSE
→
TRUE (edge):
Delete error flag "transmit buffer overflow"
FALSE: function is not executed
CLEAR_TX_BUFFER
BOOL
FALSE
→
TRUE (edge):
Delete data in the transmit buffer
FALSE: function is not executed
CLEAR_RESET_FLAG
BOOL
FALSE
→
TRUE (edge):
Delete the flags "nodes reset" and "communications
interface reset".
FALSE: function is not executed
Summary of Contents for Ecomat 100 ecomatmobile SmartController CR2500