20
ifm
System Manual
ecomat
mobile
SmartController (CR2500, CR2502) V05
Configurations
Set up programming system
POUs in the folder
CAN_OPEN
Description
SELECT_NODESTATE for
PDM,
CAN operation as master or slave:
Converts the value of the node status [BYTE] into the corresponding text [STRING]:
4
→
'STOPPED'
5
→
'OPERATIONAL'
127
→
'PRE-OPERATIONAL'
POUs in the folder
I_O_CONFIGURATION
Description
CONF_IO_CRnnnn for
Controller,
CAN operation with layer 2 or as master or slave:
Parameterises the operating modes of the inputs and outputs.
POUs in the folder
PDM_COM_LAYER2
Description
PLC_TO_PDM for
Controller,
CAN operation with layer 2 or as slave:
Organises the communication from the Controller to the PDM:
- monitors the transmission time,
- transmits control data for image change, input values etc.
TO_PDM for
Controller,
CAN operation with layer 2 or as slave:
Organises the signals for LEDs and keys between Controller and PDM.
Contains the following parameterised POUs:
- PACK (
→
3S),
- PLC_TO_PDM (
→
up),
- UNPACK (
→
3S).
POUs in the folder
CONTROL_CR10nn
Description
CONTROL_PDM for
PDM,
CAN operation with layer 2 or as master or slave:
Organises the image control in the PDM.
Contains the following parameterised POUs:
- PACK (
→
3S),
- PDM_MAIN_MAPPER,
- PDM_PAGECONTROL,
- PDM_TO_PLC (
→
down),
- SELECT_PAGE (
→
down).