ifm
System Manual
ecomat
mobile
SmartController (CR2500, CR2502) V05
PWM in the ecomatmobile controller
Hydraulic control in PWM
185
Name
Data type Description
MANUAL
BYTE
Value = 0: the controller operates in a self-optimising way.
Value > 0: the self-optimising performance of the controller is
overwritten (typical: 50).
Parameters of the function outputs
Name
Data type Description
DESIRED_CURRENT
WORD
Desired current value in [mA] for OCC
(for monitoring purposes)
ACTUAL_CURRENT
WORD
Actual current on the PWM output in [mA]
(for monitoring purposes)
BREAK BOOL
Error:
wire
to the valve interrupted
SHORT BOOL
Error:
short-circuit in the wire to the valve