20
9.2 RS422 Communication Port Connection
9.2.1 RS422 Connection (Single FINGER006 Connection
)
RS422/RS232 converter (INC400) is required to use RS422 communication between
the
FINGER006
and a host computer. Please follow the instructions.
- Connect RS422-TX(+) (Gray wire) of the
FINGER006
to RS422-RX(+) port of the
converter.
- Connect RS422-TX(-) (Yellow wire) of the
FINGER006
to RS422-RX(-) port of the
converter.
- Connect RS422-RX(+) (Brown wire) of the
FINGER006
to RS422-TX(+) port of the
converter.
- Connect RS422-RX(-) (Blue wire) of the
FINGER006
to RS422-TX(-) port of the
converter.
- Plug in the RS232 9pin connector of the converter to the COM1 or COM2 Port of the PC.
- Install and run the
FINGER006
Application Software.
Figure: RS422 Communication between FINGER006 and the PC
9.2.2 RS422 Connection (Multiple FINGER006 Connections)
RS422/RS232 converter is required to use RS422 communication between multiple
FINGER006
units and a host PC. Please follow the next instructions.
First, you have to connect all RS422 port of all
FINGER006s
in parallel.
- Connect RS422-TX(+) of one
FINGER006
to RS422-TX(+) of another
FINGER006
.
- Connect RS422-TX(-) of one
FINGER006
to RS422-TX(-) of another
FINGER006
.
- Connect RS422-RX(+) of one
FINGER006
to RS422-RX(+) of another
FINGER006
.
Summary of Contents for Star FINGER006
Page 1: ...User s Manual Fingerprint Identification Proximity PIN Reader...
Page 26: ...26 12 1 SETUP MENU F1...
Page 31: ...31 12 2 SETUP MENU F2...
Page 38: ...38 12 4 SETUP MENU F4...
Page 39: ...39...
Page 49: ...49 16 Template...