14
7.1.2 Recommended Cable Type and Permissible Length of Cable
Reference
Description
Cable Specification
Maximum
Distance
①
Controller Power (DC12V)
DC Power
Controller
Belden #9409, 18 AWG
2 conductor, unshielded
30m
②
Reader (Power and Data)
FINGER006
Controller
Belden #9512, 22 AWG
4 conductor, shielded
150m
Belden #9514, 22 AWG
8 conductor, shielded
③
Door Contact
Exit Button
Sensor Input
Input
Controller
Belden #9512, 22 AWG
4 conductor, shielded
300m
Belden #9514, 22 AWG
8 conductor, shielded
④
Door Lock, Alarm Device
Lock (Alarm)
Controller
Belden #9409, 18AWG
2 conductor, unshielded
300m
⑤
RS232 Cable
Belden #9829, 24 AWG
2-twisted pair, shielded
15m
Converter
Host P.C.
⑥
RS485 Cable
Belden #9829, 24 AWG
2-twisted pair, shielded
1,200m
Controller
Converter
Controller
Controller
Controller
FINGER006
FINGER006
FINGER006
FINGER006
Converter
RS422 Cable
Belden #9830, 24 AWG
3-twisted pair, shielded
Controller
Converter
Controller
Controller
Controller
FINGER006
FINGER006
FINGER006
FINGER006
Converter
*
Thicker wires are necessary if the connected reader consumes a higher current.