IDT Hot-Plug and Hot-Swap
PES16T4AG2 User Manual
7 - 2
May 23, 2013
Notes
Figure 7.2 Hot-Plug with Switch on Add-In Card Application
Figure 7.3 Hot-Plug with Carrier Card Application
The PCI Express Base Specification revision 1.0a allowed a hot-plug attention indicator, power indicator
and attention button to be located on the board on which the slot is implemented or on the add-in board.
When located on the add-in board, state changes are communicated between the hot-plug controller asso-
ciated with the slot and the add-in card via hot-plug messages. This capability was removed in revision 1.1
of the PCI Express Base Specification and is not supported in the PES16T4AG2.
PES16T4AG2
Port 0
Port x
Port y
Upstream
Link
PCI Express
Device
PCI Express
Device
Add-In Card
...
...
...
PES16T4AG2
Port 0
Port x
Slot
Port x
Port y
Master
SMBus
SMBus I/O
Expander
Port y
Slot
Upstream
Link
Hot-Plug Signals
Carrier
Card
...
...
...
Summary of Contents for 89HPES16T4AG2
Page 8: ...IDT PES16T4AG2 User Manual 6 May 23 2013 Notes...
Page 12: ...IDT Table of Contents PES16T4AG2 User Manual iv May 23 2013 Notes...
Page 14: ...IDT List of Tables PES16T4AG2 User Manual vi May 23 2013 Notes...
Page 16: ...IDT List of Figures PES16T4AG2 User Manual viii May 23 2013 Notes...
Page 20: ...IDT Register List PES16T4AG2 User Manual xii May 23 2013 Notes...
Page 72: ...IDT SMBus Interfaces PES16T4AG2 User Manual 5 20 May 23 2013 Notes...
Page 76: ...IDT Power Management PES16T4AG2 User Manual 6 4 May 23 2013 Notes...