For details of the settings below, see ”
7.12.1 Editing control commands [COMMAND EDIT]
*
1
If you set “DELAY” to a value other than “0”, command execution is delayed according to the set value.
Control command number to be executed and remaining time before the command execution are displayed
by 100 ms.
*
2
Th
is depends on setting of “PORT”.
*
3
The send
control command data set in ”
7.12.1 Editing control commands [COMMAND EDIT]
“ is sent for
the number of bytes specified in “SIZE”.
*
4
If you set “RECV DISPLAY” to “ASCII” or “HEX”, the received data is displayed on VFD screen in “ASCII” or
“HEX”.
*
5
If you set “DELIMITER” to a value other than “NONE”, the MSD waits until it receives the set delimiter.
*
6
If you set “DELIMITER” to “NONE”, the MSD waits the receive data until the time set for “TIME OUT”
passes. If no data is received, the MSD retries.
*
7
If you set “RECV” to “NOT CHECK” for all (32) commands, the next command will be performed without
checking reply commands. If you set it to “CHECK” for only one command, the reply command is compared
with the received data in order of ”1
→
2---31
→
32”.
*
8
If received data matches “DATA” of “RECV COMMAND” registered in ”
”, the next operation will be determined according to “PROCESS” of ”
“. If you set “PROCESS” to “RETRY”, the retry operation will be
performed. If you set it to “EXEC”, the next command will be executed. If you set it to “STOP”, the next
command will not be executed even if the next command is associated.
*
9
If a delimiter or data matching reply command is not received even after the time set in ”TIME OUT” passes,
it causes timeout and retries the operation.
*
10
If any reply command is not received, the send command data is resent for the number of replies set
in ”RETRY”. If you set “RETRY” to “0”, the command is not resent.
*
11
If you set “INTERVAL” to an interval other than “0”, retry will be delayed according to the set time.
*
12
If the reply command is not sent even after retry for the number of retry times set in “RETRY,” the next
operation will be determined according to ”ERROR”. If you set “ERROR” to “EXEC”, the next command will
be executed automatically. If you set it to “STOP”, the next command will not be executed even if the
command is associated. If you turn multiple communication ports “ON”, it becomes “RETRY OVER
ERROR” unless reply commands from all communication ports to which commands are sent are received.
*
14
The connector that is set to “POWER OFF” or “POWER ON” for ”HDMI CEC control” will be controlled.
*
15
If no response from a device controlled with CEC, the next operation will be determined according to the
setting of ”
7.12.1
“. If you set “ERROR” to “EXEC”, the next command will be executed, but if you set it to
“STOP”, the next command is not executed even if the command is associated. If you set multiple outputs to
be controlled in “HDMI CEC control” and any response from all devices controlled by CEC are not sent, it
causes an error.
[COMMAND EXEC WAIT]
No. 1 DELAY: 10.5sec