MSD-804FD
User’s Guide
229
Problem
Cause/Check item/Solution
Page
Key operation
Keys do not operate.
Make sure that keys are not locked.
Since no control command is
registered by factory default, “DISPLAY
POWER” and “COMMAND A to E” keys do not work. Register and
associate control commands in order to enable these keys.
When a control command is executed using a key on the front panel,
all keys are disabled until the command is executed
or “INVALID
TIME” passes.
Immediately after start-up, all keys are disabled until the connection
of the display device is completed.
Make sure that keys are not locked.
-
Settings are not saved
or reflected to the
actual operation.
Settings of some menus will not be saved if the
“MENU/SET” key is
not pressed after setting.
-
Communication command control
Communication
command control from
the PC to the MSD
cannot be performed.
Are the following items set correctly?
For RS-232C: communication speed and data length
For LAN: IP address or subnet mask
Is COM PORT’s FUNCTION set to “RECIEVER” mode?
If it is set to “TRANSMITTER” mode, the communication command of
the MSD cannot be controlled externally.
“@ERR,6” is returned. If control command is executed by communication commands,
communication command controls are disabled until execution of
control commands finishes or “INVALID TIME” passes.
Immediately after start-up, communication command controls are
disabled until connection of the sink device is confirmed.
-
Sending control commands
Control command is
not sent.
Make sure that the registered control command and the number of
bytes are correct. Devices requiring delimiters may not execute
commands if the delimiters are not sent. If the set number of bytes is
incorrect, the control command is not sent completely or unnecessary
data is sent after the control command.
Is the registered control command linked to the desired control
command execution condition?
Is COM PORT’s FUNCTION set to “TRANSMITTER” mode?
If it is set to “TRANSMITTER” mode, the communication command of
MSD cannot be controlled externally. Set the communication port for
sending control commands to “TRANSMITTER“ mode. If using LAN,
set the IP address and other settings of connected device.