[Table 6.2] Factory default (2/5)
Function
Factory default
Set for each
I/O/bmp*
INPUT VIDEO DETECT
10000 ms. (10 seconds)
5
HDCP INPUT ENABLE
ENABLE
5
INPUT EQUALIZER
ON
5
INPUT OFF CHECK
ON
5
H START
0 (when signals are detected, it is set automatically)
4
H DISPLAY
0 (when signals are detected, it is set automatically)
4
V START
0 (when signals are detected, it is set automatically)
4
V DISPLAY
0 (when signals are detected, it is set automatically)
4
OUTPUT EQUALIZER
OFF
3
OUTPUT MODE
HDMI YCbCr4:4:4 MODE (outputs with the most suitable
mode depending on the connected display device)
2
SYNC OUTPUT
ON
1
VIDEO OUTPUT
BLUE
1
VIDEO SWITCHING
FREEZE
→
FADE OUT-IN
1
SWITCHING SPEED
350 ms.
1
WIPE COLOR
R/G/B: 0 (black)
1
OUTPUT CONNECTOR
ON
2
HDCP OUTPUT MODE
ALWAYS
2
HDCP ERROR RETRY
ETERNITY (Retrying continuously until HDCP
authentication succeeds)
2
DEEP COLOR OUTPUT
24-BIT COLOR
2
CEC CONNECTION
NOT CONNECTED
2
FRAME LOCK
OFF
-