MSD-804FD
User’s Guide
152
7.12.1
Editing control commands [COMMAND EDIT]
You can register up to 32 control commands.
[Table 7.11] Setting items of control commands
Item
Description
Range
PORT
Select “COM” or “CEC”.
COM: Communication
command [Default]
CEC: HDMI CEC
DELAY
Set the waiting time of the control command. Use this
item for devices such as projectors that requires time
to cool down after powering off.
0 ms. to 999 seconds and 999
ms.
[Default]: 0 ms.
Communication
port
*1
Set the following communication ports to “OFF” (not
sending communication commands) or “ON” (sending
communication commands). Those ports can be set
separately, and communication commands can be
sent to multiple communication ports at the same
time.
- RS1: RS-232C CH1
*6
- RS2: RS-232C CH2
*6
- OUT1B RS to OUT4B RS:OUT1B to OUT4B
*
6
*
7
(RS-232C of OUT1B to OUT4B)
- LOOP BACK: Internal loop back
- LAN1 to LAN8: LAN connections 1 to 8
*8
- OUT1B LAN to OUT4B LAN:OUT1B to OUT4B
*
7
*
8
(LAN port of OUTB1 to OUTB4B)
OFF [Default]
ON
COM SIZE
*1
Set the number of bytes to be sent starting with the
first byte.
0 byte to 30 bytes
[Default]: 0 byte
COMMAND
INPUT MODE
*1
Set the input mode of send command data. Select
“ASCII” if “DATA” of “COMMAND” consists of only 0A,
0D, and 20 to 7D of ASCII codes
; select “HEX” if
“DATA” of “COMMAND” includes other codes.
ASCII [Default]
HEX
Send command
data
*1
Set the command from the first byte according to the
number of bytes set in “COM SIZE” (up to 30 bytes).
0A, 0D, 20 to 7D of ASCII
codes (If inputting with ASCII
codes), or 00 to FF of hex (If
inputting with hex)
[Default]: 20 (Space)
(All numbers above are hex)
RECV DISPLAY
*1
Set whether received data is displayed or not.
OFF [Default]
ASCII
HEX