MSD-804FD
User’s Guide
172
7.12.5
Invalid time [INVALID TIME]
During control command execution, other operations from a port (any of front panel, RS-232C CH1, RS-232C
CH2, LAN communication command, and LAN browser) that executes control commands will be invalid.
Since the execution time of some control commands is short, you can set the waiting time from starting control
command execution to receiving the next command. The longer time either of control command execution
time or the time set in this menu will be applied as the invalid operation time. Use this menu to prevent
repeated execution caused by pressing the control command execution key twice. Only operations from ports
that execute control commands will be invalid; operations from other ports can be performed. For example, if
you execute a control command from the front panel, you cannot perform all operations from the front panel
until the control command execution time or time set in this menu passes, but you can perform operations
from LAN communication command control. However, even during invalid operation time, for controlling
power of display devices and switching inputs, you can control display devices’ power and can then switch
input only for different outputs, in order to operate several outputs successively.
・
Invalid time: 0 ms. to 999999 ms. [Default]: 0 ms.
1. To set the invalid time using menu:
MSD-804FD
Top
↓
SET key
[FUNCTION SELECT]
PRESET COMMAND
▲▼
keys: Select “PRESET COMMAND”.
↓
SET key
[PRESET COMMAND]
INVALID TIME
▲▼
keys: Se
lect “INVALID TIME”.
↓
SET key
[INVALID TIME]
0
s000ms
▲▼
keys: Set the invalid time in seconds (0 to 999).
↓
◄►keys
[INVALID TIME]
0s00
0
ms
▲▼
keys: Set the invalid time in milliseconds (0 to 999).
↓
ESC key: Returns to the previous screen.
2. To set the invalid time using commands:
@SIT: Set ineffective time during control command
@GIT: Get ineffective time during control command