MSD-804FD
User’s Guide
153
DELIMITER
*1 *2
Set the delimiter to be sent at the end of the received
data.
“NONE”: delimiter is not checked and all received data
within the set timeout will be valid.
Value other than “NONE”: delimiter is checked and
data received before delimiter will be valid.
NONE [Default]
00 to FF (Hex)
RCV CHECK
*1
*3
Set whether reply command that may be returned is
checked or not.
CHECK [Default]
NOT CHECK
TIME OUT
*1 *4 *5
Set the timeout time for reply command to a sent
command.
0 ms. to 99 seconds and 999
ms.
[Default]: 0 ms.
RETRY
*1 *4 *5
Set the number of retries to resend the same
command again if no valid response is replied.
0 to 99
[Default]: 0
INTERVAL
*1 *4 *5
Set the retry interval to resend the command.
0 ms. to 99 seconds and 999
ms.
[Default]: 0 ms.
ERROR
*1 *4 *5
Set whether the next command is to be executed or
not if no valid response is replied, even after
completing retry for the set number of retries.
STOP: [Default]
EXEC: Continue
HDMI CEC
control
*9
Set the CEC control for display devices connected to
OUT1A to OUT4A.
-: Not control [Default]
POWER OFF
POWER ON
HDBaseT CEC
Set the CEC control for display devices connected to
OUT1B to OUT4B.
-: Not control [Default]
POWER OFF
POWER ON
Process for CEC
error
*9
Set whether the next command is executed or not if no
response is replied from the display device that is
controlled with CEC.
STOP [Default]
EXEC: Continue
MEMO
Register a note up to 14 characters.
The registered note is displayed when the control
command is executed.
20 to 7D of ASCII codes
except for
2C (,)
[Default]: All spaces
*
1
If “Port” is set to “CEC”, you do not need to set this item.
*
2
If “RECV DISPLAY” is set to “OFF”, you do not need to set this item.
*
3
If “RECV DISPLAY” is set to “ASCII” or “HEX”, you do not need to set this item.
*
4
If only “LOOP BACK” of communication ports is set to “ON”, you do not need to set this item.
*
5
If all “RCV CHECK” is set to “NOT CHECK”, you do not need to set this item.
*
6
If either “RS-1” or “RS-2” is set to “ON”, set “
7.10.2 RS-232C operation mode [FUNCTION]
” to
“TRANSMITTER”. The mode of OUT1B RS to OUT4B RS is fixed at “TRANSMITTER”, no menu is
displayed.
*
7
OUT1B to OUT4B are available only if HDBaseT output option is mounted.
*
8
If any L
AN connections for “LAN1” to “LAN8” are set to “ON”, set “
” to “TRANSMITTER
”.
*
9
If “PORT” is set to ”COM”, you do not need to set this item.