25: U
SER
C
OMMUNICATION
I
NSTRUCTIONS
25-4
FT1A S
MART
A
XIS
U
SER
’
S
M
ANUAL
FT9Y-B1382
Transmit Digits (Bytes)
After conversion, the transmit data is taken out in specified digits. Possible digits depend on the selected conversion type.
Example: D10 stores 010Ch (268)
(1) Binary to ASCII conversion, Transmit digits = 2
(2) BCD to ASCII conversion, Transmit digits = 3
(3) No conversion, Transmit digits = 1
Repeat Cycles
When a data register is designated to repeat, consecutive data registers, as many as the repeat cycles, are used for transmit data
in the same conversion type and transmit digits.
Example:
Data of data registers starting with D10 is converted in BCD to ASCII and is transmitted according to the designated repeat cycles.
010Ch
D10
“0”
(30h)
“1”
(31h)
“0”
(30h)
“C”
(43h)
“0”
(30h)
“C”
(43h)
ASCII data
Binary to ASCII conversion
Transmitted data
Lowest 2 digits
010Ch
D10
Decimal
“0”
(30h)
“0”
(30h)
“2”
(32h)
“6”
(36h)
“8”
(38h)
Lowest 3 digits
“2”
(32h)
“6”
(36h)
“8”
(38h)
BCD to ASCII
00268
value
conversion
Transmitted data
ASCII data
010Ch
D10
No conversion
SOH
(01h)
FF
(0Ch)
FF
(0Ch)
Lowest 1 digit
ASCII data
Transmitted data
Data register No.:
Transmit digits:
Conversion type:
D10
2
BCD to ASCII
000Ch
D10
0022h
D11
0038h
D12
000Ch
D10
“1”
(31h)
“2”
(32h)
“3”
(33h)
“4”
(34h)
00012
Repeat 1
0022h
D11
Decimal value
00034
BCD to ASCII conversion
Repeat 2
ASCII data
(1) Repeat cycles = 2
000Ch
D10
“1”
(31h)
“2”
(32h)
“3”
(33h)
“4”
(34h)
00012
Repeat 1
0022h
D11
Decimal value
00034
BCD to ASCII conversion
Repeat 2
0038h
D12
00056
Repeat 3
“5”
(35h)
“6”
(36h)
ASCII data
(2) Repeat cycles = 3
Summary of Contents for microsmart pentra
Page 1: ...FT1A SERIES FC9Y B1382 Ladder Programming Manual ...
Page 6: ...Preface 5 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 104: ...7 DATA COMPARISON INSTRUCTIONS 7 10 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 122: ...8 BINARY ARITHMETIC INSTRUCTIONS 8 18 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 138: ...10 SHIFT ROTATE INSTRUCTIONS 10 12 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 162: ...11 DATA CONVERSION INSTRUCTIONS 11 24 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 188: ...12 CALENDAR COMPARISON INSTRUCTIONS 12 26 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 198: ...15 REFRESH INSTRUCTIONS 15 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 202: ...16 INTERRUPT CONTROL INSTRUCTIONS 16 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 266: ...20 DUAL TEACHING TIMER INSTRUCTIONS 20 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 318: ...25 USER COMMUNICATION INSTRUCTIONS 25 22 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...