10: S
HIFT
/ R
OTATE
I
NSTRUCTIONS
10-10
FT1A S
MART
A
XIS
U
SER
’
S
M
ANUAL
FT9Y-B1382
ROTR (Rotate Right)
Applicable CPU Modules
Valid Devices
For the valid device address range, see pages 6-1 and 6-2 (Basic Vol.).
Internal relays M0 through M1277 can be designated as S1. Special internal relays cannot be designated as S1.
The quantity of bits to rotate can be 1 through 15 for the word data type, or 1 through 31 for the double-word data type.
Since the ROTR instruction is executed in each scan while input is on, a pulse input from a SOTU or SOTD instruction should be used as required.
Valid Data Types
When input is on, 16- or 32-bit data of the designated source device S1 is rotated to the right by
the quantity of bits designated by device bits.
The result is set to the source device S1, and the last bit status rotated out is set to a carry (special
internal relay M8003).
S1
*****
bits
**
ROTR(*)
Before rotation:
1
0
1
0
1
0
1
0 1
1
1
1
0
1
0
0
CY
M8003
MSB
LSB
S1
0
After rotation:
1
1
1
0
0
0
0 1
1
0
0
1
0
1
1
CY
M8003
MSB
LSB
S1
1
Rotate to the right
Data Type: Word (bits to rotate = 1)
Before rotation:
1
0
1
0
1
0
1
0 1
1
1
1
0
1
0
0
CY
M8003
MSB
LSB
S1
0
After rotation:
CY
M8003
MSB
LSB
S1
Rotate to the right
1
0
1
0
1
0
1
0 1
1
1
1
0
1
0
0
Data Type: Double Word (bits to rotate = 1)
1
1
1
0
0
0
0 1
1
0
0
1
0
1
1 1
1
1
1
0
0
0
0 1
1
0
0
1
0
1
1 1
FT1A-12
FT1A-24
FT1A-40
FT1A-48
FT1A-Touch
X
X
X
X
X
Device
Function
I
Q
M
R
T
C
D
Constant
Repeat
S1 (Source 1)
Data for bit rotation
—
X
X
—
—
X
—
—
bits
Quantity of bits to rotate
—
—
—
—
—
—
—
1-15,
1-31
—
W (word)
X
When a bit device such as Q (output), M (internal relay), or R (shift register) is designated as the source, 16
points (word data type) or 32 points (double-word data type) are used.
When a word device such as D (data register) is designated as the source, 1 point (word data type) or 2 points
(double-word data type) are used.
I (integer)
—
D (double word)
X
L (long)
—
F (float)
—
Summary of Contents for microsmart pentra
Page 1: ...FT1A SERIES FC9Y B1382 Ladder Programming Manual ...
Page 6: ...Preface 5 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 104: ...7 DATA COMPARISON INSTRUCTIONS 7 10 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 122: ...8 BINARY ARITHMETIC INSTRUCTIONS 8 18 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 138: ...10 SHIFT ROTATE INSTRUCTIONS 10 12 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 162: ...11 DATA CONVERSION INSTRUCTIONS 11 24 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 188: ...12 CALENDAR COMPARISON INSTRUCTIONS 12 26 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 198: ...15 REFRESH INSTRUCTIONS 15 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 202: ...16 INTERRUPT CONTROL INSTRUCTIONS 16 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 266: ...20 DUAL TEACHING TIMER INSTRUCTIONS 20 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 318: ...25 USER COMMUNICATION INSTRUCTIONS 25 22 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...