19: P
ULSE
O
UTPUT
I
NSTRUCTIONS
19-30
FT1A S
MART
A
XIS
U
SER
’
S
M
ANUAL
FT9Y-B1382
Examples: ZRN
ZRN1 instruction timing chart
[ZRN1 instruction, S1 is specified as data register D200, S3 is specified as external input I2, D1 is specified as internal
relay M10]
When the ZRN1 instruction changes from off to on, pulses are output at the initial pulse frequency. When pulse output starts, M10
turns on and M11 turns off. When I2 changes from off to on, pulses are output at the creep pulse frequency. When I2 changes
from on to off, pulse output stops. When pulse output stops, M10 turns off and M11 turns on.
If the ZRN1 instruction input turns off during pulse output, pulse output stops. If the input turns on again, the operation starts
from the beginning. Even if the contents of the data registers are changed during pulse output, the change is not reflected in the
pulse output operation. The changed content is reflected the next time the ZRN1 instruction is started.
The changes from the initialization input are not reflected while the ZRN1 instruction input is on. If you wish to initialize the data
registers with the initialization input, turn the initialization input on after turning off the input.
D1
M10
S2
M0
ZRN
1
S1
D200
ZRN nstruction
input
ZRN1 instruction input
Pulse output ON
M10
Pulse output complete
M11
Proximity signal
I2
Output pulse
Q15
S3
I2
Initial speed
Creep speed
Summary of Contents for microsmart pentra
Page 1: ...FT1A SERIES FC9Y B1382 Ladder Programming Manual ...
Page 6: ...Preface 5 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 104: ...7 DATA COMPARISON INSTRUCTIONS 7 10 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 122: ...8 BINARY ARITHMETIC INSTRUCTIONS 8 18 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 138: ...10 SHIFT ROTATE INSTRUCTIONS 10 12 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 162: ...11 DATA CONVERSION INSTRUCTIONS 11 24 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 188: ...12 CALENDAR COMPARISON INSTRUCTIONS 12 26 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 198: ...15 REFRESH INSTRUCTIONS 15 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 202: ...16 INTERRUPT CONTROL INSTRUCTIONS 16 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 266: ...20 DUAL TEACHING TIMER INSTRUCTIONS 20 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 318: ...25 USER COMMUNICATION INSTRUCTIONS 25 22 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...