FT1A S
MART
A
XIS
U
SER
’
S
M
ANUAL
FT9Y-B1382
19-1
19:P
ULSE
O
UTPUT
I
NSTRUCTIONS
Introduction
The pulse output instructions output pulses of the specified frequency from the pulse output ports.
PULS (Pulse Output)
Note:
Configure multiple PULS (pulse output), PWM (pulse width modulation), RAMP (trapezoidal control), and ARAMP (RAMP with table)
instructions so that they do not share the same pulse output port.
However, the ZRN (zero return) instruction can be configured with the same pulse output port as the PULS (pulse output), PWM (pulse width
modulation), RAMP (trapezoidal control), and ARAMP (RAMP with table) instructions.
Applicable CPU Modules
Note:
These instructions cannot be used with FT1A-H40RC and FT1A-B40RC.
Valid Devices
Special data registers cannot be designated as S1. Internal relays M0 through M1277 can be designated as D1. Special internal relays cannot be
designated as D1. The first digit of the internal relay number must be 0 (not 1 to 7).
The PULS instructions output pulses of the specified frequency from the specified
pulse output ports.
When the input is on, pulses are output according to the control register settings
specified by S1.
The pulse control information (output on/output complete/error) is stored in the
internal relays specified by D1 as the operation status.
When the initialization input specified by S2 is turned on, the initial values
configured in the WindLDR PULS instruction dialog box, on the
Setting
tab, are
stored in the control registers.
D1
*****
S2
*****
PULS
1
S1
*****
D1
*****
S2
*****
PULS
2
S1
*****
D1
*****
S2
*****
PULS
3
S1
*****
D1
*****
S2
*****
PULS
4
S1
*****
FT1A-12
FT1A-24
FT1A-40
FT1A-48
FT1A-Touch
—
—
X (Note)
X
—
Device
Function
I
Q
M
R
T
C
D
Constant
Repeat
S1 (Source 1)
Control register
—
—
—
—
—
—
—
—
S2 (Source 2)
Initialization input
X
—
X
—
—
—
—
—
—
D1 (Destination 1)
Operation status
—
—
—
—
—
—
—
—
Summary of Contents for microsmart pentra
Page 1: ...FT1A SERIES FC9Y B1382 Ladder Programming Manual ...
Page 6: ...Preface 5 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 104: ...7 DATA COMPARISON INSTRUCTIONS 7 10 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 122: ...8 BINARY ARITHMETIC INSTRUCTIONS 8 18 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 138: ...10 SHIFT ROTATE INSTRUCTIONS 10 12 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 162: ...11 DATA CONVERSION INSTRUCTIONS 11 24 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 188: ...12 CALENDAR COMPARISON INSTRUCTIONS 12 26 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 198: ...15 REFRESH INSTRUCTIONS 15 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 202: ...16 INTERRUPT CONTROL INSTRUCTIONS 16 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 266: ...20 DUAL TEACHING TIMER INSTRUCTIONS 20 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 318: ...25 USER COMMUNICATION INSTRUCTIONS 25 22 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...