26: D
ATA
L
OG
I
NSTRUCTIONS
26-14
FT1A S
MART
A
XIS
U
SER
’
S
M
ANUAL
FT9Y-B1382
Operation Description
When M0 is turned on, the TRACE instruction is executed one time. When the TRACE instruction is executed, the data of D0
through D5 and D10 in the previous 20 scans is output to a CSV file on the SD memory card as decimal values along with the
date and time of the execution.
The saved location of CSV files is DATA0001
\
TRACE
\
RESULT. The oldest data is saved at the top of the trace data, and the latest
data is saved at the bottom of the trace data.
When the execution of the TRACE instruction completes, the completion output M100 is turned on and the CMP instruction is
executed once. The CMP instruction compares the status code stored in the execution status D100 with 0 and turns Q0 on or off.
Q0 is turned on when an error occurs in the TRACE instruction.
Output results
Triggered at:
2012/02/06 10:20:30
Scan
D0000
D0001
D0002
D0003
D0004
D0005
D0010
Old
12345
2
12345
56789
1
56789
-3.38
12345
2
12347
56789
1
56788
-3.38
12345
2
12349
56789
1
56787
-3.38
12345
2
12351
56789
1
56786
-3.38
12345
2
12353
56789
1
56785
-3.38
12345
2
12355
56789
1
56784
-3.38
12345
2
12357
56789
1
56783
-3.38
12345
2
12359
56789
1
56782
-3.38
12345
2
12361
56789
1
56781
-3.38
12345
2
12363
56789
1
56780
-3.38
12345
2
12365
56789
1
56779
-3.38
12345
2
12367
56789
1
56778
-3.38
12345
2
12369
56789
1
56777
-3.38
12345
2
12371
56789
1
56776
-3.38
12345
2
12373
56789
1
56775
-3.38
12345
2
12375
56789
1
56774
-3.38
12345
2
12377
56789
1
56773
-3.38
12345
2
12379
56789
1
56772
-3.38
New
12345
2
12381
56789
1
56771
-3.38
Summary of Contents for microsmart pentra
Page 1: ...FT1A SERIES FC9Y B1382 Ladder Programming Manual ...
Page 6: ...Preface 5 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 104: ...7 DATA COMPARISON INSTRUCTIONS 7 10 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 122: ...8 BINARY ARITHMETIC INSTRUCTIONS 8 18 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 138: ...10 SHIFT ROTATE INSTRUCTIONS 10 12 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 162: ...11 DATA CONVERSION INSTRUCTIONS 11 24 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 188: ...12 CALENDAR COMPARISON INSTRUCTIONS 12 26 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 198: ...15 REFRESH INSTRUCTIONS 15 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 202: ...16 INTERRUPT CONTROL INSTRUCTIONS 16 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 266: ...20 DUAL TEACHING TIMER INSTRUCTIONS 20 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 318: ...25 USER COMMUNICATION INSTRUCTIONS 25 22 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...