19: P
ULSE
O
UTPUT
I
NSTRUCTIONS
19-38
FT1A S
MART
A
XIS
U
SER
’
S
M
ANUAL
FT9Y-B1382
8. Reversible control enable
This setting enables or disables reversible control and selects the reversible control method from the following reversible control
modes.
There are two modes for the pulse output mode: single-pulse output mode and dual-pulse output mode. They can be combined
with reversible control as follows.
The ports used on the SmartAxis varies based on the instruction used, the combination of the pulse output mode and reversible
control, and the model used.
Note:
When using single-pulse mode on the 40-I/O type, Q16 or Q17 are used. Therefore, PULS3, PWM3, or PULS4, PWM4 cannot be used.
9. The number of step
This setting specifies the number of steps. The maximum is 18 steps.
10. Start number
When the input changes from off to on, pulse output starts with the settings for the step configured as the start number.
11. Interrupt number
When the interrupt input changes from off to on, the pulse output process for the running step is aborted, and pulse output
restarts with the settings for the step configured by the interrupt number.
Reversible control enable
0: Reversible control disabled
1: Reversible control (single-pulse output)
2: Reversible control (dual-pulse output)
Reversible control
disabled
Select this option when using pulse output
in a single direction. Pulse A and pulse B
can be used independently.
Reversible control
Single-pulse
output mode
Pulse A is used as pulse output. Pulse B on/
off is used as reversible control.
Reversible control
Dual-pulse output
mode
Pulse A is used as forward pulse (CW)
output.
Pulse B is used as reverse pulse (CCW)
output.
Instruction
Operating condition
Port used
40-I/O type
48-I/O type
Pulse output
port
Reversible
control port
Pulse output
port
Reversible
control port
ARAMP1
Reversible control disabled
Q14
—
Q14
—
Reversible control (single-pulse output)
Q14
Q16 (Note)
Q14
Q12
Reversible control (dual-pulse output)
Q14
Q15
Q14
Q15
ARAMP2
Reversible control disabled
Q15
—
Q15
—
Reversible control (single-pulse output)
Q15
Q17 (Note)
Q15
Q13
Dual-pulse mode cannot be used.
—
—
—
—
A
B
A
B
A
B
Summary of Contents for microsmart pentra
Page 1: ...FT1A SERIES FC9Y B1382 Ladder Programming Manual ...
Page 6: ...Preface 5 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 104: ...7 DATA COMPARISON INSTRUCTIONS 7 10 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 122: ...8 BINARY ARITHMETIC INSTRUCTIONS 8 18 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 138: ...10 SHIFT ROTATE INSTRUCTIONS 10 12 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 162: ...11 DATA CONVERSION INSTRUCTIONS 11 24 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 188: ...12 CALENDAR COMPARISON INSTRUCTIONS 12 26 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 198: ...15 REFRESH INSTRUCTIONS 15 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 202: ...16 INTERRUPT CONTROL INSTRUCTIONS 16 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Page 266: ...20 DUAL TEACHING TIMER INSTRUCTIONS 20 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 318: ...25 USER COMMUNICATION INSTRUCTIONS 25 22 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...