6-6
■
Voice set mode
Sets the automatic monitor function, short play and
normal recording times for voice recorder.
q
Push [EXIT/SET] several times to close a multifunc-
tion screen, if necessary.
w
Push [F-2•VOICE] to call up the voice recorder
screen.
e
Push [F-7•SET] to enter the voice set mode screen.
r
Push [F-1•
Y
] or [F-2•
Z
] to select the desired item.
t
Rotate main dial to set the desired condition or
value.
• Push and hold [F-4•DEF] for 1 sec. to select the default
condition or value.
y
Push [EXIT/SET] to exit the voice set mode screen.
[F-1•
Y
] [F-2•
Z
] [F-4•DEF]
[EXIT/SET]
[F-7•SET]
Main dial
6
VOICE RECORDER FUNCTIONS
Set the desired time period for the short play back
(when [PLAY] is pushed momentarily).
• 3 to 10 sec. in 1 sec. steps can be set.
(default: 5 sec.)
Short Play Time
5s
Set the desired time period for one-touch recording
(when [REC] is pushed momentarily).
• 5 to 30 sec. in 1 sec. steps can be set.
(default: 15 sec.)
Short Rec Time
15s
Set the recording sound quality. The sampling rate
setting is expressed in samples per second, and de-
termines the sound quality.
Although a higher sampling rate provides a better
quality sound than a lower sampling rate, the file size
becomes larger.
• SQ1 (8kHz), SQ2 (12kHz), HQ1 (16KHz), HQ2
(24kHz), SHQ (48kHz) can be set.
(default: HQ1(16kHz))
Sound Quality (Sampling Rate)
HQ1(16kHz)
Turns the recording control signal ON or OFF. (de-
fault: OFF)
• OFF
: Continues recording even when received
signal disappears or squelch closes. (de-
fault)
• ON
: Records only when received signal ap-
pears or squelch opens and stops record-
ing when received signal disappears or
squelch closes.
REC Remote
OFF