15-4
■
Firmware update—USB-Memory
When updating the firmware with the CF card or USB-
Memory, no IP address or subnet mask settings are
necessary.
q
Copy the downloaded firmware data into the USB-
Memory (“IC-R9500” folder).
• The USB-Memory must have been formatted by the IC-
R9500.
w
Insert the USB-Memory into the USB connector.
e
Push [EXIT/SET] several times to close a multi-
function screen, if necessary.
r
Push [F-7•SET] to select set mode menu screen.
t
Push [F-7•CF/USB] to select CF/USB-Memory set
menu.
y
Push and hold [F-3•FIRM UP] for 1 sec.
u
Read the displayed precautions carefully.
• Push [F-1•
Y
] or [F-2•
Z
] to scroll the text.
• Push [F-7•CANCEL] to cancel firmware updating.
i
After you read and understand all of the precau-
tions, push [F-6•OK].
• [F-6•OK] appears only following the precautions.
• Push [F-7•CANCEL] to cancel the firmware updating.
o
Push [F-2•
Y
] or [F-3•
Z
] to select the firmware file,
then push [F-4•FIRM UP].
• Push and hold [F-1•DIR/FILE] for 1 sec. to select the
USB-Memory, if CF card is selected.
!0
Read the displayed precautions carefully.
!1
If you agree, push [F-6•OK] for 1 sec. to start the
firmware update.
• Push [F-7•CANCEL] to cancel firmware updating.
!2
While loading the firmware from the CF memory
card, the dialog at left is displayed.
[EXIT/SET]
[F-2•
Z
]/[F-2•
Y
]
[F-3•FIRM UP]/[F-3•
Z
] [F-6•OK]
[F-1•
Y
]/[F-1•DIR/FILE]
[F-7•SET]/[F-7•CF/USB]
/[F-7•CANCEL]
[F-4•FIRM UP]
15
UPDATING THE FIRMWARE