13-3
D
D
Command table
13
CONTROL COMMAND
00
—
Send frequency data
01
Same as
Send mode data
command 06
02
—
Read upper/lower frequencies for
selected band
03
—
Read operating frequency
04
—
Read operating mode
05
—
Set operating frequency
06
00
Select LSB
01
Select USB
02
Select AM
03
Select CW
04
Select FSK
05
Select FM
07
Select CW-R
08
Select FSK-R
11
Select S-AM(D)
14
Select S-AM(L)
15
Select S-AM(U)
16
Select P25
07
—
Select (Last selected) VFO mode
08
—
Select memory mode
0–1219*
Select memory channel
*0–999, 1000–1099 (A00–A99),
1100–1199 (S00–S99),
1200–1219 (P0A–P9A)
0–12*
Select memory bank
*0–9, 10 (Bank-A), 11 (Bank-S),
12 (Bank-P)
09
—
Memory write
0A
—
Memory to VFO
0B
—
Memory clear
0C
—
Read offset frequency
(see p. 13-10 for details)
0D
—
Set offset frequency
(see p. 13-10 for details)
0E
00
Scan stop
01
Programmed scan (Prog 0)/
memory scan start
02
Programmed scan (Prog 0) start
03
∂
F scan start
04
Auto memory write scan start
12
Fine programmed scan start
13
Fine
∂
F scan start
22
Memory scan start
23
Select memory scan start
24
Mode select memory scan start
42
Priority scan (Prio 0) start
A0
Set
∂
F scan Fixed frequency ON
AA
Set
∂
F scan Fixed frequency OFF
A1–A7
Set
∂
F scan span (A1=±5 kHz;
A2=±10 kHz; A3=±20 kHz;
A4=±50 kHz; A5=±100 kHz;
A6=±500 kHz; A7=±1 MHz)
B0
Set as non-select channel
B1
Set as select channel
(1–9=
★
(SEL)1–9; when no data
command is specified, the previous-
ly set number or “
★
1” is selected)
B2
Set the number for select memory
scan (0=ALL; 1–9=
★
(SEL)1–9
D0
Set scan resume OFF
0E
D1
Set scan resume ON
(Close Timer)
D3
Set scan resume ON
(Close and Delay)
10
Turn duplex OFF. (Simplex)
11
Turn duplex ON. (DUP–)
12
Turn duplex ON. (DUP+)
10
00
Select 1 Hz tuning step
01
Select 10 Hz tuning step
02
Select 100 Hz tuning step
03
Select 1 kHz tuning step
04
Select 2.5 kHz tuning step
05
Select 5 kHz tuning step
06
Select 6.25 kHz tuning step
07
Select 9 kHz tuning step
08
Select 10 kHz tuning step
09
Select 12.5 kHz tuning step
10
Select 20 kHz tuning step
11
Select 25 kHz tuning step
12
Select 100 kHz tuning step
13
Select 1 MHz tuning step
14
Select Prog tuning step
11
—
Select/read attenuator (00=OFF;
06=6 dB; 10=10 dB; 12=12 dB;
18=18 dB; 20=20 dB; 24=24 dB;
30=30 dB)
12
00
Select/read the antenna below
01
30 MHz. (00=HF ANT1,
02
01=HF ANT2, 02=HF ANT3)
13
00
Announce with voice synthesizer
01
(00=all data; 01=frequency and
02
S-meter level; 02=receive mode)
14
01 + Level data [AF] level setting
(0=max. CCW to 255=max. CW)
02 + Level data [RF] level setting
(0=max. CCW to 255=11 o’clock)
03 + Level data [SQL] level setting
(0=11 o’clock to 255=max. CW)
06 + Level data [NR] level setting
(0=min. to 255=max.)
07 + Level data Left [TWIN PBT] setting or IF shift
setting (0=max. CCW, 128=center,
255=max. CW)
08 + Level data Right [TWIN PBT] setting
(0=max. CCW, 128=center,
255=max. CW)
09 + Level data [CW PITCH] setting
(0=300 Hz, 128=600 Hz,
255=900 Hz; 5 Hz steps)
0D + Level data [NOTCH1] setting
(0=low freq. to 255=high freq.)
11 + Level data [AGC] control setting (0=max.
CCW to 255=max. CW)
12 + Level data [NB] control setting
(0=max. CCW to 255=max. CW)
18 + Level data [CONTRAST] setting (0=max.
CCW to 255=max. CW)
19 + Level data [BRIGHT] setting
(0=max. CCW to 255=max. CW)
1A + Level data [NOTCH2] setting
(0=low freq. to 255=high freq.)
1B + Level data [BASS] setting
(0=max. CCW to 255=max. CW)
1C + Level data [TREBLE] setting
(0=max. CCW to 255=max. CW)
Command
Sub command
Description
Command
Sub command
Description