Application Guide - NP900 Series
212 (504
)
A996A
16=Z12Sec
Impedance Z L12 secondary ohm
17=Z23Sec
Impedance Z L23 secondary ohm
18=Z31Sec
Impedance Z L31 secondary ohm
19=Z12Angle
Impedance Z L12 angle
20=Z23Angle
Impedance Z L23 angle
21=Z31Angle
Impedance Z L31 angle
22=RL1Pri
Resistance R L1 primary ohm
23=XL1Pri
Reactance X L1 primary ohm
24=RL2Pri
Resistance R L2 primary ohm
25=XL2Pri
Reactance X L2 primary ohm
26=RL3Pri
Resistance R L3 primary ohm
27=XL3Pri
Reactance X L3 primary ohm
28=RL1Sec
Resistance R L1 secondary ohm
29=XL1Sec
Reactance X L1 secondary ohm
30=RL2Sec
Resistance R L2 secondary ohm
31=XL2Sec
Reactance X L2 secondary ohm
32=RL3Sec
Resistance R L3 secondary ohm
33=XL3Sec
Reactance X L3 secondary ohm
34=Z1Pri
Impedance Z L1 primary ohm
35=Z2Pri
Impedance Z L2 primary ohm
36=Z3Pri
Impedance Z L3 primary ohm
37=Z1Sec
Impedance Z L1 secondary ohm
38=Z2Sec
Impedance Z L2 secondary ohm
39=Z3Sec
Impedance Z L3 secondary ohm
40=Z1Angle
Impedance Z L1 angle
41=Z2Angle
Impedance Z L2 angle
42=Z3Angle
Impedance Z L3 angle
43=RSeqPri
Positive Resistance R primary ohm
44=XSeqPri
Positive Reactance X primary ohm
45=RSeqSec
Positive Resistance R secondary
ohm
46=XSeqSec
Positive Reactance X secondary
ohm
47=ZSeqPri
Positive Impedance Z primary ohm
48=ZSeqSec
Positive Impedance Z secondary
ohm
49=ZSeqAngle
Positive Impedance Z angle
50=GL1Pri
Conductance G L1 primary mS
51=BL1Pri
Susceptance B L1 primary mS
52=GL2Pri
Conductance G L2 primary mS
53=BL2Pri
Susceptance B L2 primary mS
54=GL3Pri
Conductance G L3 primary mS
55=BL3Pri
Susceptance B L3 primary mS
56=GL1Sec
Conductance G L1 secondary mS
57=BL1Sec
Susceptance B L1 secondary mS
58=GL2Sec
Conductance G L2 secondary mS
59=BL2Sec
Susceptance B L2 secondary mS
60=GL3Sec
Conductance G L3 secondary mS
61=BL3Sec
Susceptance B L3 secondary mS
62=YL1PriMag
Admittance Y L1 primary mS
63=YL2PriMag
Admittance Y L2 primary mS
64=YL3PriMag
Admittance Y L3 primary mS
65=YL1SecMag
Admittance Y L1 secondary mS
66=YL2SecMag
Admittance Y L2 secondary mS
67=YL3SecMag
Admittance Y L3 secondary mS
68=YL1Angle
Admittance Y L1 angle
69=YL2Angle
Admittance Y L2 angle
70=YL3Angle
Admittance Y L3 angle
71=G0Pri
Conductance G0 primary mS
72=B0Pri
Susceptance B0 primary mS
73=G0Sec
Conductance G0 secondary mS
74=B0Sec
Susceptance B0 secondary mS
75=Y0Pri
Admittance Y0 primary mS
76=Y0Sec
Admittance Y0 secondary mS
77=Y0Angle
Admittance Y0 angle
Outputs of the function are Start Trip and Blocked signals. Setting parameters are static
inputs for the function which are changed only by user input in the setup phase of the