806f060d-0400ffff
Array [ComputerSystemElementName] has failed.
Explanation:
The Drive 0 is part of an RAID array that is in the failed condition. To identify drives in the failed
array all member drives will report this message.
May also be shown as 806f060d0400ffff or 0x806f060d0400ffff
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0176
SNMP Trap ID:
5
Automatically notify Support:
Yes
User response:
v
Replace the hard disk drives that are indicated by a lit status LED on the drive.
v
Recreate the array.
v
Restore data from backup.
806f060d-0401ffff
Array [ComputerSystemElementName] has failed.
Explanation:
The Drive 1 is part of an RAID array that is in the failed condition. To identify drives in the failed
array all member drives will report this message.
May also be shown as 806f060d0401ffff or 0x806f060d0401ffff
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0176
SNMP Trap ID:
5
Automatically notify Support:
Yes
User response:
v
Replace the hard disk drives that are indicated by a lit status LED on the drive.
v
Recreate the array.
v
Restore data from backup.
806f060d-0402ffff
Array [ComputerSystemElementName] has failed.
Explanation:
The Drive 2 is part of an RAID array that is in the failed condition. To identify drives in the failed
array all member drives will report this message.
May also be shown as 806f060d0402ffff or 0x806f060d0402ffff
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0176
SNMP Trap ID:
5
Automatically notify Support:
Yes
User response:
v
Replace the hard disk drives that are indicated by a lit status LED on the drive.
v
Recreate the array.
806f060d-0400ffff • 806f060d-0402ffff
Chapter 6. Troubleshooting
223
Summary of Contents for Flex System x440 Compute Node
Page 1: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 2: ......
Page 3: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 34: ...22 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 50: ...38 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 68: ...56 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 498: ...486 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 570: ...558 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 578: ...566 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 583: ......
Page 584: ... Part Number 81Y1144 Printed in USA 1P P N 81Y1144 ...