3.
If the previous steps do not resolve the problem, at the next maintenance opportunity, replace the affected DIMM
(as indicated by LightPath and/or failure log entry).
4.
If PFA re-occurs on the same DIMM connector, swap the other DIMMs on the same memory channel one at a
time to a different memory channel or Processor. (check service information for this product/Install guide for
population requirements for sparing/paring modes). If PFA follows a moved DIMM to any DIMM connector on
the different memory channel, replace the moved DIMM.
5.
Check IBM support site for an applicable Service Bulletins (Service bulletins) that applies to this memory error.
(Link to IBM support service bulletins)
6.
(Trained service technician only) If problem continues to re-occur on the same DIMM connector, inspect DIMM
connector for foreign material and remove, if found. If connector is damaged, replace system board.
7.
(Trained service technician only) Remove affected Processor and inspect Processor socket pins for damaged or
mis-aligned pins. If damage is found or Processor is an upgrade part, replace system board.
8.
(Trained Service technician only) Replace affected processor.
9.
(Trained Service technician only) Replace system board.
W.58007
[W.58007] Invalid memory configuration (Unsupported DIMM Population) detected. Please verify
memory configuration is valid.
Explanation:
Unsupported DIMM Population
Severity:
Warning
User response:
Complete the following steps:
1.
Could follow an uncorrectable memory error or failed memory test. Check log and service that event first.
DIMMs disabled by other errors or actions could cause this event.
2.
Ensure that the DIMM connectors are populated according to the guidelines in the service information for this
product.
W.580A1
[W.580A1] Invalid memory configuration for Mirror Mode. Please correct memory configuration.
Explanation:
Unsupported DIMM Population for Mirror Mode
Severity:
Warning
User response:
Complete the following steps:
1.
If a DIMM connector error LED is lit, resolve the failure.
2.
Make sure that the DIMM connectors are correctly populated for mirroring mode, according to the service
information for this product.
W.580A2
[W.580A2] Invalid memory configuration for Sparing Mode. Please correct memory configuration.
Explanation:
Unsupported DIMM Population for Spare Mode
Severity:
Warning
User response:
Complete the following step:
Make sure that the DIMM connectors are correctly populated for sparing mode, according to the service information
for this product.
W.68002
[W.68002] A CMOS battery error has been detected
Explanation:
CMOS Battery Fault
Severity:
Warning
User response:
Complete the following steps:
1.
If the system was recently Installed, Moved, or Serviced, make sure the battery is properly seated.
2.
Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
3.
Replace CMOS Battery
4.
(Trained Service technician only) Replace the system board.
W.58007 • W.68002
456
IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide
Summary of Contents for Flex System x440 Compute Node
Page 1: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 2: ......
Page 3: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 34: ...22 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 50: ...38 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 68: ...56 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 498: ...486 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 570: ...558 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 578: ...566 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 583: ......
Page 584: ... Part Number 81Y1144 Printed in USA 1P P N 81Y1144 ...