If you are installing an SDLT drive, use the custom metal slide rails and
screws that come with the option package. Follow the installation
instructions that come with the option package; then, continue with step
7c.
If you are installing a full-high DLT drive, use the custom metal slide
rails and screws that are inside the 5.25-inch removable-media drive
bays. Follow the installation instructions that come with the option
package; then, continue with step 7d.
Blue slide rails
Slide rails
Filler panel
Non-hot-swap bay
Non-hot-swap
drive
a. Remove the blue snap-on slide rails from inside the filler panel.
b. Clip the slide rails onto the sides of the drive.
c. Store the filler panel for later use.
d. Align the slide rails on the drive with the guide rails in the bay; then, slide
the drive into the bay until it snaps into place.
8. Replace the one-drop SCSI signal cable in your server with a two-drop SCSI
signal cable, connecting the additional connector on the two-drop SCSI signal
cable to the rear of the removable-media drive.
9. Connect a power cable to the back of the drive. A three-drop power cable for
removable-media drives comes installed in your server. It is attached to the
standard CD-ROM drive. The connectors are keyed and can be inserted only
one way.
10. If you have other options to install or remove, do so now; otherwise, go to
“Completing the installation” on page 95.
76
xSeries 235 Type 8671: Hardware Maintenance Manual and Troubleshooting Guide
Summary of Contents for eServer xSeries 235 Type 8671
Page 1: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver ...
Page 2: ......
Page 3: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver ...
Page 34: ...24 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 50: ...40 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 134: ...124 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 164: ...154 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 170: ...160 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 183: ...Appendix B Related service information 173 ...
Page 184: ...174 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 185: ...Appendix B Related service information 175 ...
Page 186: ...176 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 187: ...Appendix B Related service information 177 ...
Page 188: ...178 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 189: ...Appendix B Related service information 179 ...
Page 190: ...180 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 200: ...190 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 201: ...Appendix B Related service information 191 ...
Page 202: ...192 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 206: ...196 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 211: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix C Notices 201 ...
Page 212: ...202 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 213: ......