Note:
See “System” on page 156 to determine which components should be replaced by a field service technician.
Error code/symptom
FRU/action
00019701
(Microprocessor 1 failed)
1.
Microprocessor 1
2. System board
00019702
(Microprocessor 2 failed)
1.
Microprocessor 2
2. System board
00180100
(A PCI adapter has requested
memory resources that are not available.)
1.
Reorder the adapters in the PCI slots. It is important that your
startup device is positioned early in the startup-device order so
that it is run by POST.
2. Ensure that the PCI adapter and all other adapters are set correctly
in the Configuration/Setup Utility program Utility program. If the
memory resource settings are not correct, change the settings.
3. If all memory resources are being used, you might need to remove
an adapter to make memory available to the PCI adapter. Disabling
the adapter BIOS on the adapter might correct the error. (See the
documentation provided with the adapter.)
00180200
(No more I/O space available
for PCI adapter)
1.
Run the Configuration/Setup Utility program.
2. Failing adapter.
3. System board.
00180300
(No more memory (above 1MB
for PCI adapter))
1.
Run the Configuration/Setup Utility program.
2. Failing adapter.
3. System board.
00180400
(No more memory (below 1MB
for PCI adapter))
1.
Run the Configuration/Setup Utility program.
2. Move the failing adapter to slot 1.
3. Failing adapter.
4. System board.
00180500
(PCI option ROM checksum
error)
1.
Remove failing PCI card.
2. System board.
00180600
(PCI to PCI bridge error)
1.
Run the Configuration/Setup Utility program.
2. Move the failing adapter to slot 1.
3. Failing adapter.
4. System board
00180700, 00180800
(General PCI error)
1.
System board
2. PCI card
00181000
(PCI error)
v
Adapter
v
System board
01295085
(ECC checking hardware test
error)
1.
System board
2. Microprocessor
01298001
(System BIOS installed on this
server does not support level of
processor)
1.
Ensure all microprocessors have the same cache size.
2. Microprocessor 1.
01298002
(System BIOS installed on this
server does not support level of
processor)
1.
Ensure all microprocessors have the same cache size.
2. Microprocessor 2.
146
xSeries 235 Type 8671: Hardware Maintenance Manual and Troubleshooting Guide
Summary of Contents for eServer xSeries 235 Type 8671
Page 1: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver ...
Page 2: ......
Page 3: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver ...
Page 34: ...24 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 50: ...40 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 134: ...124 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 164: ...154 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 170: ...160 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 183: ...Appendix B Related service information 173 ...
Page 184: ...174 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 185: ...Appendix B Related service information 175 ...
Page 186: ...176 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 187: ...Appendix B Related service information 177 ...
Page 188: ...178 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 189: ...Appendix B Related service information 179 ...
Page 190: ...180 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 200: ...190 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 201: ...Appendix B Related service information 191 ...
Page 202: ...192 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 206: ...196 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 211: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix C Notices 201 ...
Page 212: ...202 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 213: ......