Note:
See “System” on page 156 to determine which components should be replaced by a field service technician.
Message
Action
System shutoff due to VRM x over
voltage
v
Replace VRM
x
.
System shutoff due to excessive (< 240
VA) loading
1.
See “Power checkout” on page 36.
2. Cycle ac on/off.
Temperature related system shutdown
Note:
See “System” on page 156 to determine which components should be replaced by a field service technician.
Message
Action
System shutoff due to board over
temperature
(level-critical; board is over
temperature)
1.
Ensure that the system is being properly cooled
; see “System
reliability considerations” on page 41
″
.
2. Replace board.
System shutoff due to CPU x over
temperature
(level-critical; CPU
x
is over
temperature)
1.
Ensure that the system is being properly cooled
; see “System
reliability considerations” on page 41.
2. Replace CPU
x
.
System shutoff due to CPU
x
under
temperature
(level-critical; CPU
x
is under
temperature)
v
Ambient temperature must be within normal operating
specifications
; see “Features and specifications” on page 2.
System shutoff due to DASD temperature
(sensor
x
)
(level-critical; DASD area
reported temperature outside recommended
operating range)
v
Ensure that the system is being properly cooled
; see “System
reliability considerations” on page 41.
System shutoff due to high ambient
temperature
(level-critical; high ambient
temperature)
v
Ambient temperature must be within normal operating
specifications
; see “Features and specifications” on page 2.
System shutoff due to system board
under temperature
(level-critical; system
board is under temperature)
v
Ambient temperature must be within normal operating
specifications
; see “Features and specifications” on page 2.
DASD checkout
Note:
See “System” on page 156 to determine which components should be replaced by a field service technician.
Message
Action
Hard drive
x
removal detected
(level-critical; hard drive
x
has been
removed)
v
Information only, take action as appropriate.
Host built-in self test (BIST)
Note:
See “System” on page 156 to determine which components should be replaced by a field service technician.
Message
Action
Host fail
(level-informational; built-in
self-test for the host failed)
1.
Reseat the microprocessor.
2. Reseat the VRM.
3. Replace the microprocessor CPU.
150
xSeries 235 Type 8671: Hardware Maintenance Manual and Troubleshooting Guide
Summary of Contents for eServer xSeries 235 Type 8671
Page 1: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver ...
Page 2: ......
Page 3: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver ...
Page 34: ...24 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 50: ...40 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 134: ...124 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 164: ...154 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 170: ...160 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 183: ...Appendix B Related service information 173 ...
Page 184: ...174 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 185: ...Appendix B Related service information 175 ...
Page 186: ...176 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 187: ...Appendix B Related service information 177 ...
Page 188: ...178 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 189: ...Appendix B Related service information 179 ...
Page 190: ...180 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 200: ...190 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 201: ...Appendix B Related service information 191 ...
Page 202: ...192 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 206: ...196 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 211: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix C Notices 201 ...
Page 212: ...202 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 213: ......