Checkout
procedure
Complete
the
following
steps
to
perform
the
checkout
procedure:
001
IS
THE
SERVER
PART
OF
A
CLUSTER?
YES.
Schedule
maintenance
for
the
system.
Shut
down
all
systems
related
to
the
cluster.
Run
the
storage
test.
NO.
Go
to
step
002
.
002
IF
THE
SERVER
IS
NOT
PART
OF
A
CLUSTER:
1.
Check
the
power
supply
LEDs,
see
“Hot-swap
power-supply
LED
errors”
on
page
96.
2.
Turn
off
the
server
and
all
external
devices.
3.
Check
all
internal
and
external
devices
for
compatibility
at
http://www.ibm.com/servers/eserver/serverproven/compat/us/.
4.
Check
all
cables
and
power
cords.
5.
Set
all
display
controls
to
the
middle
position.
6.
Turn
on
all
external
devices.
7.
Turn
on
the
server.
8.
Record
any
POST
error
messages
that
are
displayed
on
the
screen.
If
an
error
is
displayed,
look
up
the
first
error
in
“POST
error
codes”
on
page
88.
9.
Check
the
operator
information
panel
system-error
LED;
if
it
is
on,
see
“Light
path
diagnostics
errors”
on
page
93.
10.
Check
the
system-error
log
and
the
BMC
log.
Note:
The
system-error
log
on
the
xSeries
336
server
is
available
only
with
the
Remote
Supervisor
Adapter
II
SlimLine.
If
an
error
was
recorded
by
the
server,
see
Chapter
6,
“Symptom-to-FRU
index,”
on
page
83.
11.
Start
the
diagnostic
programs.
12.
Check
for
the
following
responses:
v
One
beep
v
Readable
instructions
or
the
main
menu
003
DID
YOU
RECEIVE
BOTH
OF
THE
CORRECT
RESPONSES?
NO.
Find
the
failure
symptom
in
Chapter
6,
“Symptom-to-FRU
index,”
on
page
83.
YES.
Run
the
diagnostic
programs
(see
“Diagnostic
programs,
error
codes,
and
messages”
on
page
70).
If
you
receive
an
error,
see
Chapter
6,
“Symptom-to-FRU
index,”
on
page
83.
If
the
diagnostic
programs
were
completed
successfully
and
you
still
suspect
a
problem,
see
“Undetermined
problems”
on
page
119.
68
xSeries
336
Type
1879
and
Type
8837:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Summary of Contents for 88371RU
Page 1: ...xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 2: ......
Page 3: ...xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 15: ...Server on off 8 to 80 Shipment 5 to 100 Chapter 1 General information 5...
Page 22: ...12 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 24: ...14 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 92: ...82 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 149: ...Appendix B Safety information 139...
Page 150: ...140 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 151: ...Appendix B Safety information 141...
Page 152: ...142 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 153: ...Appendix B Safety information 143...
Page 154: ...144 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 155: ...Appendix B Safety information 145...
Page 165: ...Appendix B Safety information 155...
Page 166: ...156 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 167: ...Appendix B Safety information 157...
Page 168: ...158 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 172: ...162 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 185: ......
Page 186: ...Part Number 25K8109 1P P N 25K8109...