Chapter
5.
Diagnostics
This
section
provides
basic
troubleshooting
information
to
help
solve
some
common
problems
that
might
occur
with
the
server.
If
you
cannot
locate
and
correct
the
problem
using
the
information
in
this
section,
see
Appendix
A,
“Getting
help
and
technical
assistance,”
on
page
127
for
more
information.
General
checkout
Follow
the
checkout
procedure
(see
“Checkout
procedure”
on
page
68)
for
diagnosing
hardware
problems.
Review
the
following
information
before
performing
the
checkout
procedure:
v
Read
Appendix
B,
“Safety
information,”
on
page
129.
v
The
server
diagnostic
programs
are
stored
in
upgradeable
read-only
memory
(ROM)
on
the
system
board.
These
programs
provide
the
primary
methods
of
testing
the
major
components
of
the
server.
If
you
are
not
sure
whether
a
problem
is
caused
by
the
hardware
or
by
the
software,
you
can
run
the
diagnostic
programs
(see
“Diagnostic
programs,
error
codes,
and
messages”
on
page
70)
to
confirm
that
the
hardware
is
working
correctly.
v
When
you
run
the
diagnostic
programs,
a
single
problem
might
cause
several
error
messages.
If
you
receive
several
error
messages,
correct
the
cause
of
the
first
error
message.
The
other
error
messages
might
not
occur
the
next
time
you
run
the
diagnostic
programs.
v
Before
running
the
diagnostic
programs,
you
must
determine
whether
the
failing
server
is
part
of
a
shared
hard
disk
drive
cluster
(two
or
more
servers
sharing
external
storage
devices).
If
you
suspect
that
it
is
part
of
a
cluster,
you
can
run
all
diagnostic
programs
except
the
ones
that
test
the
storage
unit
(that
is,
a
hard
disk
drive
in
the
storage
unit)
or
the
storage
adapter
that
is
attached
to
the
storage
unit.
The
failing
server
might
be
part
of
a
cluster
if
any
of
the
following
conditions
is
true:
–
The
customer
identifies
the
failing
server
as
part
of
a
cluster.
–
One
or
more
external
storage
units
are
attached
to
the
failing
server
and
at
least
one
of
the
attached
storage
units
is
also
attached
to
another
server
or
unidentifiable
device.
–
One
or
more
servers
are
located
near
the
failing
server.
v
Important:
1.
For
servers
that
are
part
of
a
shared
hard
disk
drive
cluster,
run
one
test
at
a
time.
Do
not
run
any
suite
of
tests,
such
as
“quick”
or
“normal”
tests,
because
this
could
enable
the
hard
disk
drive
diagnostic
tests.
2.
If
more
than
one
error
code
is
displayed,
correct
the
first
error.
The
other
error
codes
might
not
occur
the
next
time
you
run
the
diagnostic
programs.
3.
If
the
server
is
suspended
and
a
POST
error
code
is
displayed,
see
“POST
error
codes”
on
page
88.
4.
If
the
server
is
suspended
and
no
error
message
is
displayed,
see
“Error
symptoms”
on
page
103
and
“Undetermined
problems”
on
page
119.
5.
For
information
about
power-supply
problems,
see
“Power
checkout”
on
page
79.
6.
For
intermittent
problems,
check
the
error
logs;
see
“Diagnostic
programs,
error
codes,
and
messages”
on
page
70.
©
Copyright
IBM
Corp.
2002,
2007
67
Summary of Contents for 88371RU
Page 1: ...xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 2: ......
Page 3: ...xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 15: ...Server on off 8 to 80 Shipment 5 to 100 Chapter 1 General information 5...
Page 22: ...12 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 24: ...14 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 92: ...82 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 149: ...Appendix B Safety information 139...
Page 150: ...140 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 151: ...Appendix B Safety information 141...
Page 152: ...142 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 153: ...Appendix B Safety information 143...
Page 154: ...144 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 155: ...Appendix B Safety information 145...
Page 165: ...Appendix B Safety information 155...
Page 166: ...156 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 167: ...Appendix B Safety information 157...
Page 168: ...158 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 172: ...162 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Page 185: ......
Page 186: ...Part Number 25K8109 1P P N 25K8109...