v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Type 7940 and 7941 servers,” on page 19 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
BMC log message
Sensor
type
Sensor
number
Action
CPU 1 Temp UNR Asserted
CPU 2 Temp UNR Asserted
CPU 1 Temp UC Asserted
CPU 2 Temp UC Asserted
01h
01h
01h
01h
98h
99h
98h
99h
1. Make sure that the fans are operating,
that there are no obstructions to the
airflow, that the air baffles are in place and
correctly installed, and that the server
cover is installed and completely closed.
2. (Trained service technician only) Make
sure that the heat sink for CPU n is
installed correctly.
3. (Trained service technician only) Replace
CPU n.
4. (Trained service technician only) Replace
the system board.
CPU 1 Temp UNC Asserted
CPU 2 Temp UNC Asserted
01h
01h
98h
99h
1. Make sure that the fans are operating,
that there are no obstructions to the
airflow, that the air baffles are in place and
correctly installed, and that the server
cover is installed and completely closed.
2. (Trained service technician only) Make
sure that the heat sink for CPU n is
installed correctly.
CPU 1 Temp UNR Deasserted
CPU 1 Temp UC Deasserted
CPU 1 Temp UNC Deasserted
CPU 2 Temp UNR Deasserted
CPU 2 Temp UC Deasserted
CPU 2 Temp UNC Deasserted
01h
01h
01h
01h
01h
01h
98h
98h
98h
99h
99h
99h
Information only
FP Cable Absent
1Bh
83h
1. Reseat the front panel cable.
2. Replace the front panel cable.
3. Replace the front panel.
FP Cable Present
1Bh
83h
Information only
CPU 1 Thermal Trip Asserted
CPU 2 Thermal Trip Asserted
07h
07h
90h
91h
1. Make sure that the fans are operating,
that there are no obstructions to the
airflow, that the air baffles are in place and
correctly installed, and that the server
cover is installed and completely closed.
2. (Trained service technician only) Make
sure that the heat sink for CPU n is
installed correctly.
3. (Trained service technician only) Replace
CPU n.
CPU 1 Thermal Trip Deasserted
CPU 2 Thermal Trip Deasserted
07h
07h
90h
91h
Information only
CPU 1 Presense Detected Asserted
CPU 2 Presense Detected Asserted
07h
07h
90h
91h
Information only
112
IBM System x3455 Type 7940 and 7941: Problem Determination and Service Guide
Summary of Contents for 7940
Page 1: ...IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Page 2: ......
Page 3: ...IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Page 8: ...vi IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Page 18: ...xvi IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Page 32: ...14 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Page 36: ...18 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Page 46: ...28 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Page 142: ...124 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Page 152: ...134 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Page 158: ...140 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Page 159: ......
Page 160: ... Part Number 49Y0088 Printed in USA 1P P N 49Y0088 ...