Table
6.
Service
Processor
Error
Codes.
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
406E
00A6
Scan
control
routine
detected
no
usable
memory
1.
Ensure
that
memory
DIMMs
and
cards
are
properly
installed.
2.
Go
to
service
processor
memory
configuration/deconfiguration
menu
to
verify
memory
DIMMs
state.
See
″
Memory
Configuration/Deconfiguration
Menu
″
on
page
384
for
more
information.
3.
Go
to
“MAP
1540:
Minimum
Configuration”
on
page
113.
406E
00A7
Scan
control
routine
detected
hardware
problem
Go
to
“MAP
1540:
Minimum
Configuration”
on
page
113.
406E
00B0
Scan
control
routine
detected
bus
controller
lock-unlock
failure
RIO
adapter
Location:
U0.1-P1.1
406E
00B1
Scan
control
routine
detected
bus
controller
failure
RIO
adapter
Location:
U0.1-P1.1
406E
00B7
Scan
control
routines
detected
insufficient
hardware
resources
to
continue
IPL
This
error
code
appears
after
the
initial
testing
by
the
service
processor
firmware
on
the
CEC
was
completed
correctly,
but
a
problem
occurred
when
the
firmware
tried
to
communicate
outside
the
CEC.
Suspect
a
problem
with
the
RIO
interface,
either
cables
or
adapters.
406E
0100
Scan
control
routine
detected
memory
riser
card
fault
Memory
riser
card
Location:
U1.1-P1-M2
406E
0101
Scan
control
routine
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.15
406E
0102
Scan
control
routine
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.1
406E
0103
Scan
control
routine
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.16
406E
0104
Scan
control
routine
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.2
406E
010D
Scan
control
routine
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.1
x4
406E
0111
Scan
control
routine
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.13
406E
0112
Scan
control
routine
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.3
406E
0113
Scan
control
routine
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.14
406E
0114
Scan
control
routine
detected
memory
DIMM
fault
Memory
DIMM
Location:
U1.1-P1-M2.4
260
Service
Guide
Summary of Contents for 6H0
Page 2: ......
Page 12: ...x Service Guide ...
Page 16: ...xiv Service Guide ...
Page 18: ...xvi Service Guide ...
Page 28: ...R CEC Drawer 5 EIA Units Primary I O Drawer 5 EIA Units 8 Service Guide ...
Page 29: ...CEC Drawer Front View 1 1 Power On LED Chapter 1 Reference Information 9 ...
Page 33: ...5 Fan 4 U0 1 F4 6 Fan 3 U0 1 F3 Chapter 1 Reference Information 13 ...
Page 37: ...5 Fan 4 U0 2 F4 6 Fan 3 U0 2 F3 Chapter 1 Reference Information 17 ...
Page 77: ...DC Power Cable Routings Chapter 1 Reference Information 57 ...
Page 88: ...68 Service Guide ...
Page 94: ...74 Service Guide ...
Page 182: ...162 Service Guide ...
Page 444: ...424 Service Guide ...
Page 468: ...Replacement Replace in reverse order 448 Service Guide ...
Page 489: ...Chapter 10 Parts Information This chapter contains parts information for the system 469 ...
Page 490: ...CEC Drawer 1 2 3 4 9 10 12 11 7 8 6 5 14 14 13 15 16 17 18 18 19 20 470 Service Guide ...
Page 493: ...1 2 3 4 5 6 7 8 9 10 11 Chapter 10 Parts Information 473 ...
Page 497: ...7 8 9 10 6 1 2 3 4 4 5 Chapter 10 Parts Information 477 ...
Page 510: ...490 Service Guide ...
Page 522: ...502 Service Guide ...
Page 546: ...526 Service Guide ...
Page 552: ...532 Service Guide ...
Page 559: ......