Table
5.
Firmware
Error
Codes.
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
203w
0xyz
Remote
I/O
(RIO)
configuration
warning.
This
code
indicates
that
an
RIO
configuration
was
detected
that
does
not
result
in
complete
loops.
The
system
continues
to
boot,
however,
performance
or
recovery
capability
may
be
reduced.
In
some
cases,
the
problem
may
result
in
missing
I/O.
Remote
I/O
drawers
are
connected
in
loops.
Use
the
letters
w,
y,
and
z
in
the
error
code
to
isolate
the
location
of
the
open
loop.
Check
RIO
cables
for
loose
connections,
and
verify
power
on
the
I/O
drawers
by
the
presence
of
fan
motion.
The
following
numbers
may
be
used
to
help
isolate
the
failing
component.
v
w
=
loop
number,
this
is
either
0
or
1
in
a
system
with
2
RIO
loops.
v
x
=
Always
0.
v
y
is
either
1
or
2
on
a
system
with
2
loops.
y
indicates
the
nearest
associated
RIO
port
number
on
the
CEC
drawer
according
to
the
following
table:
y
=
Nearest
RIO
Port
1
=
0
2
=
1
v
z
=
B,
indicates
a
missing
return
line
from
the
I/O
drawer
to
the
CEC
drawer.
v
z
=
C,
indicates
a
missing
link
between
two
I/O
drawers.
v
z
=
E,
indicates
an
I/O
drawer
was
found
connected
to
RIO
port
3
with
no
return
to
the
CEC
drawer,
and
no
I/O
drawer
was
found
connected
to
RIO
port
2.
In
this
case,
the
I/O
connected
to
RIO
port
3
is
removed
from
the
configuration
because
the
cause
of
the
error
and
the
proper
location
of
the
I/O
cannot
be
determined.
1.
Check
the
RIO
cables
2.
Go
to
“MAP
1540:
Minimum
Configuration”
on
page
113.
20A8
0000
Insufficient
information
to
boot.
Verify
the
IP
address.
20A8
0001
Client
IP
address
is
already
in
use
by
other
network
device
Change
IP
address.
Chapter
5.
Error
Code
to
FRU
Index
191
Summary of Contents for 6H0
Page 2: ......
Page 12: ...x Service Guide ...
Page 16: ...xiv Service Guide ...
Page 18: ...xvi Service Guide ...
Page 28: ...R CEC Drawer 5 EIA Units Primary I O Drawer 5 EIA Units 8 Service Guide ...
Page 29: ...CEC Drawer Front View 1 1 Power On LED Chapter 1 Reference Information 9 ...
Page 33: ...5 Fan 4 U0 1 F4 6 Fan 3 U0 1 F3 Chapter 1 Reference Information 13 ...
Page 37: ...5 Fan 4 U0 2 F4 6 Fan 3 U0 2 F3 Chapter 1 Reference Information 17 ...
Page 77: ...DC Power Cable Routings Chapter 1 Reference Information 57 ...
Page 88: ...68 Service Guide ...
Page 94: ...74 Service Guide ...
Page 182: ...162 Service Guide ...
Page 444: ...424 Service Guide ...
Page 468: ...Replacement Replace in reverse order 448 Service Guide ...
Page 489: ...Chapter 10 Parts Information This chapter contains parts information for the system 469 ...
Page 490: ...CEC Drawer 1 2 3 4 9 10 12 11 7 8 6 5 14 14 13 15 16 17 18 18 19 20 470 Service Guide ...
Page 493: ...1 2 3 4 5 6 7 8 9 10 11 Chapter 10 Parts Information 473 ...
Page 497: ...7 8 9 10 6 1 2 3 4 4 5 Chapter 10 Parts Information 477 ...
Page 510: ...490 Service Guide ...
Page 522: ...502 Service Guide ...
Page 546: ...526 Service Guide ...
Page 552: ...532 Service Guide ...
Page 559: ......