v
Enable/Disable
Console
Mirroring
Console
mirroring
is
supported
on
serial
port
1
(S1)
and
serial
port
2
(S2).
When
console
mirroring
is
enabled,
the
service
processor
sends
information
to
both
serial
ports.
The
serial
port
from
which
console
mirroring
is
enabled
is
referred
to
as
the
active
port
.
The
mirror
port
is
determined
when
keyboard
input
is
detected
from
the
other
port.
From
this
point
on,
the
service
processor
only
sends
information
to
the
active
port
and
the
mirror
port.
This
capability
can
be
enabled
by
local
or
remote
users,
providing
local
users
the
capability
to
monitor
remote
sessions.
Console
mirroring
can
be
enabled
for
the
current
session
only.
For
more
information,
see
“Console
Mirroring”
on
page
407.
v
Start
Talk
Mode
In
a
console
mirroring
session,
it
is
useful
for
those
who
are
monitoring
the
session
to
be
able
to
communicate
with
each
other.
Selecting
this
menu
item
activates
the
keyboards
and
displays
for
such
communications
while
console
mirroring
is
established.
This
is
a
full
duplex
link,
so
message
interference
is
possible.
Alternating
messages
between
users
works
best.
v
OS
Surveillance
Setup
Menu
This
menu
can
be
used
to
set
up
operating
system
(OS)
surveillance.
OS
Surveillance
Setup
Menu
1.
Surveillance:
Currently
Enabled
2.
Surveillance
Time
Interval:
5
minutes
3.
Surveillance
Delay:
10
minutes
98.
Return
to
Previous
Menu
1>
–
Surveillance
Can
be
set
to
Enabled
or
Disabled.
–
Surveillance
Time
Interval
Can
be
set
to
any
number
from
2
through
255.
–
Surveillance
Delay
Can
be
set
to
any
number
from
0
through
255.
Refer
to
“Service
Processor
System
Monitoring
-
Surveillance”
on
page
404
for
more
information
about
surveillance.
v
Reset
Service
Processor
If
this
option
is
selected,
entering
Y
causes
the
service
processor
to
reboot.
376
Service
Guide
Summary of Contents for 6H0
Page 2: ......
Page 12: ...x Service Guide ...
Page 16: ...xiv Service Guide ...
Page 18: ...xvi Service Guide ...
Page 28: ...R CEC Drawer 5 EIA Units Primary I O Drawer 5 EIA Units 8 Service Guide ...
Page 29: ...CEC Drawer Front View 1 1 Power On LED Chapter 1 Reference Information 9 ...
Page 33: ...5 Fan 4 U0 1 F4 6 Fan 3 U0 1 F3 Chapter 1 Reference Information 13 ...
Page 37: ...5 Fan 4 U0 2 F4 6 Fan 3 U0 2 F3 Chapter 1 Reference Information 17 ...
Page 77: ...DC Power Cable Routings Chapter 1 Reference Information 57 ...
Page 88: ...68 Service Guide ...
Page 94: ...74 Service Guide ...
Page 182: ...162 Service Guide ...
Page 444: ...424 Service Guide ...
Page 468: ...Replacement Replace in reverse order 448 Service Guide ...
Page 489: ...Chapter 10 Parts Information This chapter contains parts information for the system 469 ...
Page 490: ...CEC Drawer 1 2 3 4 9 10 12 11 7 8 6 5 14 14 13 15 16 17 18 18 19 20 470 Service Guide ...
Page 493: ...1 2 3 4 5 6 7 8 9 10 11 Chapter 10 Parts Information 473 ...
Page 497: ...7 8 9 10 6 1 2 3 4 4 5 Chapter 10 Parts Information 477 ...
Page 510: ...490 Service Guide ...
Page 522: ...502 Service Guide ...
Page 546: ...526 Service Guide ...
Page 552: ...532 Service Guide ...
Page 559: ......