Sample
File
modem_z0.cfg
#
#
COMPONENT_NAME:
(ESPSETUP)
ENTRY
SERVICE
PROCESSOR
SETUP
Z0
#
#
FUNCTIONS:
Modem
configuration
file
for
some
early
Hayes*
compatible
modems.
#
This
example
uses
the
ATZ0
reset
command
to
choose
the
factory
defaults.
#
This
setup
is
recommended
for
modems
that
will
respond
to
the
ATZ0
command
#
and
which
do
not
respond
to
the
extended
(&)
commands.
Refer
to
your
modem
#
manual.
#
#
*
Trademark
of
Hayes
Microcomputer
Products,
Inc.
#
#
(C)
COPYRIGHT
International
Business
Machines
Corp.
1996
#
All
Rights
Reserved
#
Licensed
Materials
-
Property
of
IBM
#
#
US
Government
Users
Restricted
Rights
-
Use,
duplication
or
#
disclosure
restricted
by
GSA
ADP
Schedule
Contract
with
IBM
Corp.
#
#
#
If
the
modem
has
configuration
switches,
they
should
be
set
to
the
#
factory
default
settings.
ICDelay
1
DefaultTO
10
CallDelay
120
#
AT
Attention
Code
,
Inserts
delay
in
dialing
commands
#
Z0
Reset.
Restore
Profile
0
Q0
Turn
on
responses
#
E0
Turn
echo
off
Q1
Turn
off
responses
#
V0
Use
numeric
responses
S0=0
Automatic
answer
inhibit
#
+++
Escape
to
command
mode
S0=2
Answer
on
second
ring
#
H0
Hang-up
X0=0
Limit
modem
response
codes
#
T
=
Tone
mode.
When
used
as
T\r,
it
is
a
#
no
op
to
maintain
program
synchronization
#
when
modem
may/will
echo
the
commands.
#
#
%N
Call-Out
phone
number
%P
Paging
phone
number
#
%S
Modem
speed
(available
to
users)
#
#
Following
are
common
responses
from
a
wide
range
of
modems:
#
16,
15,
12,
10,
5
and
1
are
connection
responses.
Add
others
as
required.
#
7=busy;
6=no
dial
tone;
4=error;
3=no
carrier;
2=ring;
0=OK
#
#
PROGRAMMING
NOTE:
No
blanks
between
double
quote
marks
(").
condout:
send
"ATZ0Q0T\r"
#
Reset
modem.
Select
profile
0
ignore
"0\r"
or
"OK\r\n"
timeout
2
#
Ignore
modem
response.
send
"ATE0T\r"
#
Initialize
modem:
Echo
OFF,
expect
"0\r"
or
"OK\r\n"
timeout
2
#
Enable
responses
(Numeric),
send
"ATQ0V0X0T\r"
#
Limit
response
codes.
expect
"0\r"
timeout
2
#
Confirm
commands
successful.
send
"ATS0=0\r"
#
Set
AutoAnswer
OFF
expect
"0\r"
timeout
2
#
Confirm
command
successful.
done
connect:
send
"ATDT%N\r"
#
Tone
dialing
command.
#
%N
from
Call
Home
setup.
#
Expect
a
connection
response.
expect
"16\r"
or
"15\r"
or
"14\r"
or
"12\r"
or
"10\r"
or
"5\r"
or
"1\r"
busy
"7\r"
timeout
60
done
retry:
send
"A/"
#
Repeat
the
previous
command.
#
Expect
a
connection
response.
Appendix
D.
Modem
Configurations
517
Summary of Contents for 6H0
Page 2: ......
Page 12: ...x Service Guide ...
Page 16: ...xiv Service Guide ...
Page 18: ...xvi Service Guide ...
Page 28: ...R CEC Drawer 5 EIA Units Primary I O Drawer 5 EIA Units 8 Service Guide ...
Page 29: ...CEC Drawer Front View 1 1 Power On LED Chapter 1 Reference Information 9 ...
Page 33: ...5 Fan 4 U0 1 F4 6 Fan 3 U0 1 F3 Chapter 1 Reference Information 13 ...
Page 37: ...5 Fan 4 U0 2 F4 6 Fan 3 U0 2 F3 Chapter 1 Reference Information 17 ...
Page 77: ...DC Power Cable Routings Chapter 1 Reference Information 57 ...
Page 88: ...68 Service Guide ...
Page 94: ...74 Service Guide ...
Page 182: ...162 Service Guide ...
Page 444: ...424 Service Guide ...
Page 468: ...Replacement Replace in reverse order 448 Service Guide ...
Page 489: ...Chapter 10 Parts Information This chapter contains parts information for the system 469 ...
Page 490: ...CEC Drawer 1 2 3 4 9 10 12 11 7 8 6 5 14 14 13 15 16 17 18 18 19 20 470 Service Guide ...
Page 493: ...1 2 3 4 5 6 7 8 9 10 11 Chapter 10 Parts Information 473 ...
Page 497: ...7 8 9 10 6 1 2 3 4 4 5 Chapter 10 Parts Information 477 ...
Page 510: ...490 Service Guide ...
Page 522: ...502 Service Guide ...
Page 546: ...526 Service Guide ...
Page 552: ...532 Service Guide ...
Page 559: ......