Table
5.
Firmware
Error
Codes.
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
2803
0001
RTC
not
updating
-
RTC
initialization
required
Errors
reported
against
the
real-time
clock
can
be
caused
by
low
battery
voltage
and
(more
rarely)
power
outages
that
occur
during
normal
system
usage.
These
errors
are
warnings
that
the
real-time
clock
data
content
needs
to
be
re-established
and
do
not
require
any
FRU
replacement
unless
the
error
is
persistent.
When
one
of
these
errors
occurs,
the
time
and
date
information
has
been
lost.
To
set/restore
the
time
and
date,
use
the
operating
system
facility.
If
the
error
is
persistent:
1.
Replace
the
battery.
2.
Replace
primary
I/O
backplane
Location:
U0.1-P1
2803
0002
Bad
time/date
values
1.
Set
time
and
date.
2.
Refer
to
Action
under
error
code
28030001.
2803
0003
RTC
not
updating
-
not
correctable
Replace
primary
I/O
backplane
Location:
U0.1-P1
2803
0004
RTC
operating
mode
parameters
(eg.
data
mode)
changed
1.
Set
time
and
date.
2.
Refer
to
Action
under
error
code
28030001.
2803
0005
RTC
battery
error
1.
Replace
the
battery.
Note:
Password,
time,
and
date
need
to
be
set.
2.
Refer
to
Action
under
error
code
28030001.
2900
0002
Keyboard/mouse
controller
failed
self-test
Replace
primary
I/O
backplane
Location:
U0.1-P1
29A0
0003
Keyboard
not
present/detected
1.
Keyboard
2.
Keyboard
cable
3.
Replace
primary
I/O
backplane
Location:
U0.1-P1
29A0
0004
Keyboard
stuck
key
detected
1.
Keyboard
2.
Replace
primary
I/O
backplane
Location:
U0.1-P1
29B0
0004
Mouse
not
present/detected
1.
Mouse
2.
Replace
primary
I/O
backplane
Location:
U0.1-P1
Chapter
5.
Error
Code
to
FRU
Index
211
Summary of Contents for 6H0
Page 2: ......
Page 12: ...x Service Guide ...
Page 16: ...xiv Service Guide ...
Page 18: ...xvi Service Guide ...
Page 28: ...R CEC Drawer 5 EIA Units Primary I O Drawer 5 EIA Units 8 Service Guide ...
Page 29: ...CEC Drawer Front View 1 1 Power On LED Chapter 1 Reference Information 9 ...
Page 33: ...5 Fan 4 U0 1 F4 6 Fan 3 U0 1 F3 Chapter 1 Reference Information 13 ...
Page 37: ...5 Fan 4 U0 2 F4 6 Fan 3 U0 2 F3 Chapter 1 Reference Information 17 ...
Page 77: ...DC Power Cable Routings Chapter 1 Reference Information 57 ...
Page 88: ...68 Service Guide ...
Page 94: ...74 Service Guide ...
Page 182: ...162 Service Guide ...
Page 444: ...424 Service Guide ...
Page 468: ...Replacement Replace in reverse order 448 Service Guide ...
Page 489: ...Chapter 10 Parts Information This chapter contains parts information for the system 469 ...
Page 490: ...CEC Drawer 1 2 3 4 9 10 12 11 7 8 6 5 14 14 13 15 16 17 18 18 19 20 470 Service Guide ...
Page 493: ...1 2 3 4 5 6 7 8 9 10 11 Chapter 10 Parts Information 473 ...
Page 497: ...7 8 9 10 6 1 2 3 4 4 5 Chapter 10 Parts Information 477 ...
Page 510: ...490 Service Guide ...
Page 522: ...502 Service Guide ...
Page 546: ...526 Service Guide ...
Page 552: ...532 Service Guide ...
Page 559: ......