SPCN
Error
Codes
Attention:
If
a
power
supply
or
fan
is
hot-swapped,
wait
five
minutes,
then
recheck
the
AIX
error
log.
If
the
system
has
to
be
shut
down
to
replace
a
power
supply
or
fan,
reboot
the
system,
wait
five
minutes
after
the
AIX
login
prompt
appears,
then
recheck
the
AIX
error
log.
If
the
detailed
information
for
the
most
recent
error
with
the
same
identifier
indicates
that
the
original
problem
has
not
been
fixed
by
performing
the
first
action
in
the
action
column,
continue
with
the
next
action
in
the
action
column.
Attention:
If
you
replace
FRUs
or
perform
an
action
and
the
problem
is
still
not
corrected,
go
to
“MAP
1540:
Minimum
Configuration”
on
page
113
unless
otherwise
indicated
in
the
tables.
If
you
replace
FRUs
and
the
problem
is
corrected,
go
to
″
MAP
410:
Repair
Checkout
″
in
the
RS/6000
and
Eserver
pSeries
Diagnostics
Information
for
Multiple
Bus
Systems
.
Table
4.
SPCN
Error
Codes
Error
Code
Description
Action/
Possible
Failing
FRU
1011
00AC
AC
loss
or
brownout
detected
Information
message
1011
00EF
Room
emergency
power
off
detected
Information
message
1011
1510
Power
supply
1
power
source
failure
1.
Check
input
power
to
the
power
supply
2.
Primary
I/O
drawer
power
supply
1
Location:
U0.1-V1
3.
Primary
I/O
backplane
Location:
U0.1-P1
1011
1511
Power
supply
1
fault
1.
Primary
I/O
drawer
power
supply
1
Location:
U0.1-V1
2.
Primary
I/O
backplane
Location:
U0.1-P1
1011
1512
Power
supply
1
non-power
fault
1.
Primary
I/O
drawer
power
supply
1
Location:
U0.1-V1
2.
Primary
I/O
backplane
Location:
U0.1-P1
1011
1513
Power
supply
1
domain
fault
1.
Primary
I/O
drawer
power
supply
1
Location:
U0.1-V1
2.
Primary
I/O
backplane
Location:
U0.1-P1
1011
1514
Power
supply
1
cooling
fault
1.
Primary
I/O
drawer
power
supply
1
Location:
U0.1-V1
2.
Primary
I/O
backplane
Location:
U0.1-P1
Chapter
5.
Error
Code
to
FRU
Index
169
Summary of Contents for 6H0
Page 2: ......
Page 12: ...x Service Guide ...
Page 16: ...xiv Service Guide ...
Page 18: ...xvi Service Guide ...
Page 28: ...R CEC Drawer 5 EIA Units Primary I O Drawer 5 EIA Units 8 Service Guide ...
Page 29: ...CEC Drawer Front View 1 1 Power On LED Chapter 1 Reference Information 9 ...
Page 33: ...5 Fan 4 U0 1 F4 6 Fan 3 U0 1 F3 Chapter 1 Reference Information 13 ...
Page 37: ...5 Fan 4 U0 2 F4 6 Fan 3 U0 2 F3 Chapter 1 Reference Information 17 ...
Page 77: ...DC Power Cable Routings Chapter 1 Reference Information 57 ...
Page 88: ...68 Service Guide ...
Page 94: ...74 Service Guide ...
Page 182: ...162 Service Guide ...
Page 444: ...424 Service Guide ...
Page 468: ...Replacement Replace in reverse order 448 Service Guide ...
Page 489: ...Chapter 10 Parts Information This chapter contains parts information for the system 469 ...
Page 490: ...CEC Drawer 1 2 3 4 9 10 12 11 7 8 6 5 14 14 13 15 16 17 18 18 19 20 470 Service Guide ...
Page 493: ...1 2 3 4 5 6 7 8 9 10 11 Chapter 10 Parts Information 473 ...
Page 497: ...7 8 9 10 6 1 2 3 4 4 5 Chapter 10 Parts Information 477 ...
Page 510: ...490 Service Guide ...
Page 522: ...502 Service Guide ...
Page 546: ...526 Service Guide ...
Page 552: ...532 Service Guide ...
Page 559: ......