Table
5.
Firmware
Error
Codes.
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
20FB
003A
Failure
to
read
I/O
drawer
SPCN
address
1.
Check
RIO
cable
connections
2.
Check
for
system
firmware
update
3.
Replace
RIO
card
assembly
4.
Replace
I/O
backplane
if
not
already
replaced
(location
code
indicates
which
drawer)
20FB
0040
Failed
to
match
SPCN
address
to
SPCN
node
entry
address.
1.
Check
RIO
cable
connections
2.
Check
for
system
firmware
update
3.
Replace
RIO
card
assembly
4.
Replace
I/O
backplane
if
not
already
replaced
(location
code
indicates
which
drawer)
20FB
0050
Service
processor
mailbox
failed
to
update
SPCN
configuration
table.
1.
Check
RIO
cable
connections
2.
Check
for
service
processor
firmware
update
3.
Replace
primary
I/O
drawer
backplane
Location:
U0.1-P1
20FB
99xy
The
number
of
I/O
drawers
reported
by
RIO
does
not
match
the
number
of
I/O
drawers
reported
by
SPCN,
where
x
is
the
number
of
drawers
reported
by
RIO
and
y
is
the
number
of
drawers
reported
by
SPCN.
This
error
code
should
cause
the
system
to
hang.
1.
Check
RIO
and
SPCN
cabling.
2.
If
there
is
an
error
code
displayed
by
any
of
the
secondary
I/O
drawers,
perform
the
actions
for
that
error
code.
3.
If
there
is
no
error
code
displayed
by
any
of
the
secondary
I/O
drawers,
examine
the
service
processor
error
logs
to
obtain
an
error
code.
4.
RIO
Bus
Adapter
Location:
U0.2-P1.1
5.
Secondary
I/O
Backplane
Location:
U0.2-P1
20FC
0xxx
Retrieving
power,
package,
cooling
VPD
via
SPCN
for
the
CEC
and
I/O
drawers
20FC
0010
Failed
to
match
RIO
addressing
with
SPCN
node
entry
address.
Replace
I/O
backplane
if
not
already
replaced
(location
code
indicates
which
drawer)
196
Service
Guide
Summary of Contents for 6H0
Page 2: ......
Page 12: ...x Service Guide ...
Page 16: ...xiv Service Guide ...
Page 18: ...xvi Service Guide ...
Page 28: ...R CEC Drawer 5 EIA Units Primary I O Drawer 5 EIA Units 8 Service Guide ...
Page 29: ...CEC Drawer Front View 1 1 Power On LED Chapter 1 Reference Information 9 ...
Page 33: ...5 Fan 4 U0 1 F4 6 Fan 3 U0 1 F3 Chapter 1 Reference Information 13 ...
Page 37: ...5 Fan 4 U0 2 F4 6 Fan 3 U0 2 F3 Chapter 1 Reference Information 17 ...
Page 77: ...DC Power Cable Routings Chapter 1 Reference Information 57 ...
Page 88: ...68 Service Guide ...
Page 94: ...74 Service Guide ...
Page 182: ...162 Service Guide ...
Page 444: ...424 Service Guide ...
Page 468: ...Replacement Replace in reverse order 448 Service Guide ...
Page 489: ...Chapter 10 Parts Information This chapter contains parts information for the system 469 ...
Page 490: ...CEC Drawer 1 2 3 4 9 10 12 11 7 8 6 5 14 14 13 15 16 17 18 18 19 20 470 Service Guide ...
Page 493: ...1 2 3 4 5 6 7 8 9 10 11 Chapter 10 Parts Information 473 ...
Page 497: ...7 8 9 10 6 1 2 3 4 4 5 Chapter 10 Parts Information 477 ...
Page 510: ...490 Service Guide ...
Page 522: ...502 Service Guide ...
Page 546: ...526 Service Guide ...
Page 552: ...532 Service Guide ...
Page 559: ......