Operator
Panel
Error
Codes
Attention:
If
you
replace
FRUs
or
perform
an
action
and
the
problem
is
still
not
corrected,
go
to
“MAP
1540:
Minimum
Configuration”
on
page
113
unless
otherwise
indicated
in
the
tables.
If
you
replace
FRUs
and
the
problem
is
corrected,
go
to
″
MAP
410:
Repair
Checkout
″
in
the
RS/6000
and
Eserver
pSeries
Diagnostics
Information
for
Multiple
Bus
Systems
.
Table
3.
Operator
Panel
Error
Codes.
Error
Code
Description
Action/
Possible
Failing
FRU
0000
1111
At
power
on,
failure
of
power-good
signal
from
power
supply.
1.
Primary
I/O
backplane
Location:
U0.1-P1
2.
Primary
I/O
power
supply
Locations:
U0.1-V1
U0.1-V2
0000
1112
At
power
off,
failure
of
power-good
signal
from
power
supply.
1.
Primary
I/O
backplane
Location:
U0.1-P1
2.
Primary
I/O
power
supply
Locations:
U0.1-V1
U0.1-V2
0000
1113
While
power
on,
failure
of
power-good
signal
from
power
supply.
1.
Primary
I/O
backplane
Location:
U0.1-P1
2.
Primary
I/O
power
supply
Locations:
U0.1-V1
U0.1-V2
0000
1114
Operator
panel
and
service
processor
have
been
reset
after
main
power
disturbance.
Information
message
0000
2222
Operator
panel
not
communicating
with
service
processor
1.
If
system
cannot
be
powered
off,
reset
the
service
processor
(via
the
pinhole
reset
or
by
disconnecting
then
reconnecting
power).
2.
Primary
I/O
backplane
Location:
U0.1-P1
0000
3333
SPCN
communications
error
Primary
I/O
backplane
Location:
U0.1-P1
0000
3334
I2C
repeater
error
Primary
I/O
backplane
Location:
UO.1-P1
0000
BBBB
TOD
battery
malfunction
TOD
battery
Location:
U0.1-P1-V3
168
Service
Guide
Summary of Contents for 6H0
Page 2: ......
Page 12: ...x Service Guide ...
Page 16: ...xiv Service Guide ...
Page 18: ...xvi Service Guide ...
Page 28: ...R CEC Drawer 5 EIA Units Primary I O Drawer 5 EIA Units 8 Service Guide ...
Page 29: ...CEC Drawer Front View 1 1 Power On LED Chapter 1 Reference Information 9 ...
Page 33: ...5 Fan 4 U0 1 F4 6 Fan 3 U0 1 F3 Chapter 1 Reference Information 13 ...
Page 37: ...5 Fan 4 U0 2 F4 6 Fan 3 U0 2 F3 Chapter 1 Reference Information 17 ...
Page 77: ...DC Power Cable Routings Chapter 1 Reference Information 57 ...
Page 88: ...68 Service Guide ...
Page 94: ...74 Service Guide ...
Page 182: ...162 Service Guide ...
Page 444: ...424 Service Guide ...
Page 468: ...Replacement Replace in reverse order 448 Service Guide ...
Page 489: ...Chapter 10 Parts Information This chapter contains parts information for the system 469 ...
Page 490: ...CEC Drawer 1 2 3 4 9 10 12 11 7 8 6 5 14 14 13 15 16 17 18 18 19 20 470 Service Guide ...
Page 493: ...1 2 3 4 5 6 7 8 9 10 11 Chapter 10 Parts Information 473 ...
Page 497: ...7 8 9 10 6 1 2 3 4 4 5 Chapter 10 Parts Information 477 ...
Page 510: ...490 Service Guide ...
Page 522: ...502 Service Guide ...
Page 546: ...526 Service Guide ...
Page 552: ...532 Service Guide ...
Page 559: ......