Diagnostic Error Code
FRU to replace/action to take
006-000-
XXX
Diskette interface Test Passed
No action
006-0
XX
-
XXX
Diskette interface error
1.
Diskette drive Cable
2. Diskette drive
3. System board
006-195-
XXX
Diskette interface Test aborted by user
1.
Information
2. Restart the test, if you need to.
006-196-
XXX
Diskette interface test halt, error threshold
exceeded
1.
Press F3 to review the log file. See
“Viewing the Test Log” on
page 4-8.
2. Restart the test to reset the log file.
006-197-
XXX
Diskette interface test warning
1.
Make sure that the component that
is called out is enabled or
connected.
2. Rerun the test.
3. Component that is called out in
warning statement
4. Component under test
006-198-
XXX
Diskette interface test aborted
1.
If a component is called out, make
sure that it is enabled or
connected.
2. Flash the system and retest.
3. Go to “Undetermined Problems” on
page 3-22.
006-199-
XXX
Diskette interface test failed, cause
unknown
1.
Go to “Undetermined Problems” on
page 3-22.
2. Flash the system and retest.
3. Replace component under function
test.
006-25X-
XXX
Diskette interface Error
1.
Diskette drive Cable
2. Diskette drive
3. System board
011-000-
XXX
Serial port Interface Test Passed
No action
011-001-
XXX
Serial port Presence
1.
Remove external serial device, if
present.
2. Run setup, enable port.
3. System board
011-002-
XXX
011-003-
XXX
Serial port Timeout/Parity error
System board
011-013-
XXX
011-014-
XXX
Serial port Control Signal/Loopback test
failure
System board
011-015-
XXX
Serial port External Loopback failure
1.
Wrap plug
2. System board
011-027-
XXX
Serial port Configuration/Setup error
1.
Run Setup, enable port.
2. Flash the system.
3. System board
4-14
3745-XXA 4-14 3746-9X0: 6578 SPIM
Summary of Contents for 3746-900
Page 2: ......
Page 10: ...viii 3745 XXA viii 3746 9X0 6578 SPIM ...
Page 20: ...xviii 3745 XXA xviii 3746 9X0 6578 SPIM ...
Page 70: ...1 50 3745 XXA 1 50 3746 9X0 6578 SPIM ...
Page 118: ...3 38 3745 XXA 3 38 3746 9X0 6578 SPIM ...
Page 160: ...5 16 3745 XXA 5 16 3746 9X0 6578 SPIM ...
Page 162: ...6 2 3745 XXA 6 2 3746 9X0 6578 SPIM ...
Page 172: ...A 10 3745 XXA A 10 3746 9X0 6578 SPIM ...
Page 173: ...Appendix A Safety Information A 11 ...
Page 180: ...A 18 3745 XXA A 18 3746 9X0 6578 SPIM ...
Page 184: ...B 2 3745 XXA B 2 3746 9X0 6578 SPIM ...
Page 190: ...C 6 3745 XXA C 6 3746 9X0 6578 SPIM ...
Page 194: ...E 2 3745 XXA E 2 3746 9X0 6578 SPIM ...
Page 214: ...G 10 3745 XXA G 10 3746 9X0 6578 SPIM ...
Page 231: ...Appendix I Service Processor Part Numbers Copyright IBM Corp 2001 I 1 ...
Page 234: ...I 4 3745 XXA I 4 3746 9X0 6578 SPIM ...
Page 263: ......