3745 FRU Exchange Procedure
Installation Procedure
1. Install the new EPO assembly and fasten it
with the four screws
.8/
.
2. Reconnect the cable
.7/
.
3. Re-install the PS2 cover
.4/
with the four
screws
.3/
.
4. Slide the primary power box in the frame and
fasten it with the four screws
.2/
.
5. Reconnect the ground wire
.1/
to the frame.
6. Reconnect all the cables to their proper posi-
tion at the front side and at the rear side of
the primary power box.
7. Reconnect the main power cable in outlet J3.
8. Set the Customer power supply switch to ON,
and remove the safety panel previously
installed. panel.
9. Switch CB1 ON.
10. Close the front and rear door.
11. Press Power On on the control panel.
12. Referring to Chapter 3, “How to Run 3745
Diagnostics” on page 3-1, run the same diag-
nostic that you ran before you exchanged the
FRU.
13. Go to “Action to Take After a Diagnostic Run
or an FRU Exchange” on page 4-99.
4-76
3745 Models 130 to 17A: MIP
Summary of Contents for 3745 130
Page 2: ......
Page 10: ...viii 3745 Models 130 to 17A MIP ...
Page 16: ...xiv 3745 Models 130 to 17A MIP ...
Page 23: ...Safety Figure 0 2 Ground Wire Connection on Controller Expansion Safety xxi ...
Page 46: ...Safety xliv 3745 Models 130 to 17A MIP ...
Page 47: ...Safety Safety xlv ...
Page 48: ...Safety xlvi 3745 Models 130 to 17A MIP ...
Page 49: ...Safety Safety xlvii ...
Page 50: ...Safety xlviii 3745 Models 130 to 17A MIP ...
Page 51: ...Safety Safety xlix ...
Page 52: ...Safety l 3745 Models 130 to 17A MIP ...
Page 53: ...Safety Safety li ...
Page 54: ...Safety lii 3745 Models 130 to 17A MIP ...
Page 55: ...Safety Safety liii ...
Page 56: ...Safety liv 3745 Models 130 to 17A MIP ...
Page 57: ...Safety Safety lv ...
Page 58: ...Safety lvi 3745 Models 130 to 17A MIP ...
Page 66: ...Safety lxiv 3745 Models 130 to 17A MIP ...
Page 68: ...Preface lxvi 3745 Models 130 to 17A MIP ...
Page 70: ...Amendments lxviii 3745 Models 130 to 17A MIP ...
Page 154: ...3745 MAPs 1 84 3745 Models 130 to 17A MIP ...
Page 200: ...Service Processor MAPs 2 46 3745 Models 130 to 17A MIP ...
Page 226: ...Diagnostics 3 26 3745 Models 130 to 17A MIP ...
Page 253: ...FRU Exchange Location 01S Figure 4 31 3745 EPO Chapter 4 3745 FRU Exchange 4 27 ...
Page 332: ...CE leaving procedure 4 106 3745 Models 130 to 17A MIP ...
Page 338: ...Maintenance Aids A 6 3745 Models 130 to 17A MIP ...
Page 354: ...Abbreviation X 6 3745 Models 130 to 17A MIP ...
Page 359: ......
Page 360: ...IBM Part Number 03F5017 Printed in Denmark by IBM Danmark A S ð3F5ð17 SY33 2ð7ð ð9 ...