Diagnostics
Options Menu
à
@
ð
CUSTOMER ID:
3745
SERIAL NUMBER:
CCU-A SELECTED PROCESS MOSS-OFFLINE
X71:ð2ð415
X72:ðððð85
-------------------------------------------------------------- ð3/ð6/87 ðð:15
FUNCTION ON SCREEN: OFFLINE DIAGS
:
R RERUN REQUEST
:
A ABORT ROUTINE
:
C CANCEL REQUEST
:
G GO
:
M MODIFY OPTIONS: :
S/LS/AL/ALS/B/DM :
NW/W
: START ð9:58:15
C1/CNNN/C
: REQUEST: CCU
DIAGNOSTICS INITIALIZATION
R1/RNNN
: OPTIONS: S
NW C1
R1
BR
BR/NBR
:
: ENTER REQUEST ACCORDING TO THE DIAG MENU
: ==>M R2
===>
F1:END F2:MENU2 F3:ALARM
á
ñ
Figure
3-6. How to Enter Options
When the OPT field is set to Y in the diagnostic
menu, the options menu is displayed. See
Figure 3-6.
The default options are automatically displayed.
Options:
Meaning
S
Stop on first error.
LS
Loop on first error with stop.
AL
Automatic loop on error.
ALS
Automatic loop on error with new
error stop.
B
Bypass error stop.
DM
Display multiple errors.
NW
No wait before execution of each
routine.
W
Wait before execution of each
routine.
C1/CNNN/C Cycle request option.
R1/RNNN
Repeat routine option.
BR/NBR
BER recording option.
1. Enter or modify the option using the M func-
tion followed by the option or options needed
(for example : M C5 DM will cause your
request to cycle 5 times and display multiple
errors).
Only one option per line of the menu can be
selected. If more than one option is entered,
only the last one is accepted.
2. Press SEND
Restart the same procedure to enter the other
options if needed.
3. Enter G
4. Press SEND.
The diagnostic is started and the diagnostic
result is displayed on this frame.
If an error is detected, an error message is
displayed. See Figure 3-7 on page 3-12.
Chapter 3. How to Run 3745 Diagnostics
3-11
Summary of Contents for 3745 130
Page 2: ......
Page 10: ...viii 3745 Models 130 to 17A MIP ...
Page 16: ...xiv 3745 Models 130 to 17A MIP ...
Page 23: ...Safety Figure 0 2 Ground Wire Connection on Controller Expansion Safety xxi ...
Page 46: ...Safety xliv 3745 Models 130 to 17A MIP ...
Page 47: ...Safety Safety xlv ...
Page 48: ...Safety xlvi 3745 Models 130 to 17A MIP ...
Page 49: ...Safety Safety xlvii ...
Page 50: ...Safety xlviii 3745 Models 130 to 17A MIP ...
Page 51: ...Safety Safety xlix ...
Page 52: ...Safety l 3745 Models 130 to 17A MIP ...
Page 53: ...Safety Safety li ...
Page 54: ...Safety lii 3745 Models 130 to 17A MIP ...
Page 55: ...Safety Safety liii ...
Page 56: ...Safety liv 3745 Models 130 to 17A MIP ...
Page 57: ...Safety Safety lv ...
Page 58: ...Safety lvi 3745 Models 130 to 17A MIP ...
Page 66: ...Safety lxiv 3745 Models 130 to 17A MIP ...
Page 68: ...Preface lxvi 3745 Models 130 to 17A MIP ...
Page 70: ...Amendments lxviii 3745 Models 130 to 17A MIP ...
Page 154: ...3745 MAPs 1 84 3745 Models 130 to 17A MIP ...
Page 200: ...Service Processor MAPs 2 46 3745 Models 130 to 17A MIP ...
Page 226: ...Diagnostics 3 26 3745 Models 130 to 17A MIP ...
Page 253: ...FRU Exchange Location 01S Figure 4 31 3745 EPO Chapter 4 3745 FRU Exchange 4 27 ...
Page 332: ...CE leaving procedure 4 106 3745 Models 130 to 17A MIP ...
Page 338: ...Maintenance Aids A 6 3745 Models 130 to 17A MIP ...
Page 354: ...Abbreviation X 6 3745 Models 130 to 17A MIP ...
Page 359: ......
Page 360: ...IBM Part Number 03F5017 Printed in Denmark by IBM Danmark A S ð3F5ð17 SY33 2ð7ð ð9 ...