3745 MAPs
Power MAP 3970: PCC-Detected Error on CCU Reset or on Remote
Power OFF
Symptom Explanation
Conditions That Could Cause This Symptom
Incorrect states/sequencing in CCU
reset signals.
SCTL
PUC
PCC
PS1
Cable from 01A-Y0A3 to 01G-A1YP on page 1-52
Cable from 01A-Y0A2 to 01G-A1YR on page 1-52
001
– Power the 3745 OFF as follows:
Set the power control to local mode:
– Using Power Control, scroll till the
value is 3.
– Press Validate.
Press Power Off.
– Disconnect cable connector 01A-Y0A3 from the
MOSS board. Refer to Figure 4-9 on
page 4-11.
– Press Power On Reset.
does the same error appear?
Yes No
002
(From step 008)
– Reconnect the cable connector.
– Exchange the PUC card (01G-V)
– Press Power On Reset.
Does the same error appear?
Yes No
003
Go to “CE Leaving Procedure” on
page 4-102.
004
– Press Power Off.
– Exchange the PUC card (01G-V)
– Exchange the SCTL card (01G-W)
– Press Power On Reset.
does the same error appear?
Yes No
005
Go to “CE Leaving Procedure” on
page 4-102.
006
Suspect the cable from 01A-Y0A3 to
01G-A1YP on page 1-52 or the cable
01A-Y0A2 to 01G-A1YR on page 1-52 or
Basic board.
007
– Reconnect the cable connector.
– Disconnect cable connector 01A-Y0-A2 from the
MOSS board. Refer to Figure 4-9 on
page 4-11.
– Press Power On Reset.
does the same error appear?
Yes No
008
Go to Step 002
009
– Reconnect the cable connector.
– Press Power Off.
– Exchange the PCC card (01A-X0B)
2-30
3745 Models 130 to 17A: MIP
Summary of Contents for 3745 130
Page 2: ......
Page 10: ...viii 3745 Models 130 to 17A MIP ...
Page 16: ...xiv 3745 Models 130 to 17A MIP ...
Page 23: ...Safety Figure 0 2 Ground Wire Connection on Controller Expansion Safety xxi ...
Page 46: ...Safety xliv 3745 Models 130 to 17A MIP ...
Page 47: ...Safety Safety xlv ...
Page 48: ...Safety xlvi 3745 Models 130 to 17A MIP ...
Page 49: ...Safety Safety xlvii ...
Page 50: ...Safety xlviii 3745 Models 130 to 17A MIP ...
Page 51: ...Safety Safety xlix ...
Page 52: ...Safety l 3745 Models 130 to 17A MIP ...
Page 53: ...Safety Safety li ...
Page 54: ...Safety lii 3745 Models 130 to 17A MIP ...
Page 55: ...Safety Safety liii ...
Page 56: ...Safety liv 3745 Models 130 to 17A MIP ...
Page 57: ...Safety Safety lv ...
Page 58: ...Safety lvi 3745 Models 130 to 17A MIP ...
Page 66: ...Safety lxiv 3745 Models 130 to 17A MIP ...
Page 68: ...Preface lxvi 3745 Models 130 to 17A MIP ...
Page 70: ...Amendments lxviii 3745 Models 130 to 17A MIP ...
Page 154: ...3745 MAPs 1 84 3745 Models 130 to 17A MIP ...
Page 200: ...Service Processor MAPs 2 46 3745 Models 130 to 17A MIP ...
Page 226: ...Diagnostics 3 26 3745 Models 130 to 17A MIP ...
Page 253: ...FRU Exchange Location 01S Figure 4 31 3745 EPO Chapter 4 3745 FRU Exchange 4 27 ...
Page 332: ...CE leaving procedure 4 106 3745 Models 130 to 17A MIP ...
Page 338: ...Maintenance Aids A 6 3745 Models 130 to 17A MIP ...
Page 354: ...Abbreviation X 6 3745 Models 130 to 17A MIP ...
Page 359: ......
Page 360: ...IBM Part Number 03F5017 Printed in Denmark by IBM Danmark A S ð3F5ð17 SY33 2ð7ð ð9 ...