3745 Control Panel
How to Perform 3745 Control Panel Operations
Important
Before working on non-customer access areas
of the 3745, power control should be set to
Local Mode. This can be done as follows:
1. Using Power Control, scroll till the value
is 3, Local Mode.
2. Press Validate.
Power On Reset
To perform this function:
Start from machine power OFF with Service
Mode either 0 or 1 and the default value for Func-
tion digit at 0.
1. Allow a 10-second delay from power OFF.
2. Press Power On Reset.
A power ON reset sequence will be executed fol-
lowed by a general IPL. At successful completion
of the operation, the display will be as follows:
0FF4
x 3
x x x x
Or, when NCP is IPLed from the hard disk:
0000
x 3
x x x x
x = variable values.
General IPL
1. Using Function, scroll till the value is 0,
General IPL.
2. Press Validate.
A general reset, MOSS IML, CCU IPL, and a
scanner IML is executed and the CLDP is loaded.
At successful completion of the operation, the
display will be as follows:
0FF4
x 3
x x x x
Or, when NCP is IPLed from the hard disk:
0000
x 3
x x x x
x = variable values.
MOSS IML
1. Using Function, scroll till the value is 1,
MOSS IML.
2. Press Validate.
3. This initiates a MOSS reset followed by a
MOSS IML.
At successful completion of the operation, the
display will be as follows:
When MOSS was alone prior to the IML:
1F0E
x 3
x x x x
Or, when MOSS was not alone prior to the IML:
1F0F
x 3
x x x x
x = variable values.
MOSS Dump
1. Using Function, scroll till the value is 2,
MOSS DUMP.
2. Press Validate. A MOSS reset and dump of
MOSS microcode onto disk will be executed.
At successful conclusion of the operation, the
display will be as follows:
2F01
x 3
x x x x
x = variable values.
3. Perform a MOSS IML to return to normal
mode (see preceding procedure).
1-82
3745 Models 130 to 17A: MIP
Summary of Contents for 3745 130
Page 2: ......
Page 10: ...viii 3745 Models 130 to 17A MIP ...
Page 16: ...xiv 3745 Models 130 to 17A MIP ...
Page 23: ...Safety Figure 0 2 Ground Wire Connection on Controller Expansion Safety xxi ...
Page 46: ...Safety xliv 3745 Models 130 to 17A MIP ...
Page 47: ...Safety Safety xlv ...
Page 48: ...Safety xlvi 3745 Models 130 to 17A MIP ...
Page 49: ...Safety Safety xlvii ...
Page 50: ...Safety xlviii 3745 Models 130 to 17A MIP ...
Page 51: ...Safety Safety xlix ...
Page 52: ...Safety l 3745 Models 130 to 17A MIP ...
Page 53: ...Safety Safety li ...
Page 54: ...Safety lii 3745 Models 130 to 17A MIP ...
Page 55: ...Safety Safety liii ...
Page 56: ...Safety liv 3745 Models 130 to 17A MIP ...
Page 57: ...Safety Safety lv ...
Page 58: ...Safety lvi 3745 Models 130 to 17A MIP ...
Page 66: ...Safety lxiv 3745 Models 130 to 17A MIP ...
Page 68: ...Preface lxvi 3745 Models 130 to 17A MIP ...
Page 70: ...Amendments lxviii 3745 Models 130 to 17A MIP ...
Page 154: ...3745 MAPs 1 84 3745 Models 130 to 17A MIP ...
Page 200: ...Service Processor MAPs 2 46 3745 Models 130 to 17A MIP ...
Page 226: ...Diagnostics 3 26 3745 Models 130 to 17A MIP ...
Page 253: ...FRU Exchange Location 01S Figure 4 31 3745 EPO Chapter 4 3745 FRU Exchange 4 27 ...
Page 332: ...CE leaving procedure 4 106 3745 Models 130 to 17A MIP ...
Page 338: ...Maintenance Aids A 6 3745 Models 130 to 17A MIP ...
Page 354: ...Abbreviation X 6 3745 Models 130 to 17A MIP ...
Page 359: ......
Page 360: ...IBM Part Number 03F5017 Printed in Denmark by IBM Danmark A S ð3F5ð17 SY33 2ð7ð ð9 ...